AP07-PT-93180YC-04# show inter nve 1 nve1 is down (Administratively down) admin state is down, Hardware: NVE MTU 9216 bytes Encapsulation VXLAN Auto-mdix is turned off RX ucast: 6100 pkts, 902800 bytes - mcast: 90910 pkts, 13119120 bytes TX ucast: 6357 pkts, 937212 bytes - mcast: 31481 pkts, 4267286 bytes AP07-PT-93180YC-04# show nve peers AP07-PT-93180YC-04# ------------->Should not see vxlan routes after shutdown the interface vni 1. AP07-PT-93180YC-04# show ip route vrf ran IP Route Table for VRF "RAN" '*' denotes best ucast next-hop '**' denotes best mcast next-hop '[x/y]' denotes [preference/metric] '%' in via output denotes VRF 0.0.0.0/0, ubest/mbest: 2/0 *via 192.168.3.3%default, [200/0], 00:16:38, bgp-65160, internal, tag 22394, segid: 40003 tunnelid: 0xc0a80303 encap: VXLAN *via 192.168.3.4%default, [200/0], 00:16:38, bgp-65160, internal, tag 22394, segid: 40003 tunnelid: 0xc0a80304 encap: VXLAN 10.10.10.0/24, ubest/mbest: 1/0, attached *via 10.10.10.1, Vlan3000, [0/0], 07:54:57, direct 10.10.10.1/32, ubest/mbest: 1/0, attached *via 10.10.10.1, Vlan3000, [0/0], 07:54:57, local 10.14.0.0/16, ubest/mbest: 2/0 *via 192.168.3.3%default, [200/0], 00:16:38, bgp-65160, internal, tag 65160, segid: 40003 tunnelid: 0xc0a80303 encap: VXLAN *via 192.168.3.4%default, [200/0], 00:16:38, bgp-65160, internal, tag 65160, segid: 40003 tunnelid: 0xc0a80304 encap: VXLAN 10.14.120.0/24, ubest/mbest: 1/0, attached *via 10.14.120.1, Vlan120, [0/0], 07:54:58, direct 10.14.120.1/32, ubest/mbest: 1/0, attached *via 10.14.120.1, Vlan120, [0/0], 07:54:58, local 10.14.121.0/24, ubest/mbest: 1/0, attached *via 10.14.121.1, Vlan121, [0/0], 07:54:58, direct 10.14.121.1/32, ubest/mbest: 1/0, attached *via 10.14.121.1, Vlan121, [0/0], 07:54:58, local 10.14.121.52/32, ubest/mbest: 1/0, attached *via 10.14.121.52, Vlan121, [190/0], 07:53:03, hmm 10.14.122.0/24, ubest/mbest: 1/0, attached *via 10.14.122.1, Vlan122, [0/0], 07:54:58, direct 10.14.122.1/32, ubest/mbest: 1/0, attached *via 10.14.122.1, Vlan122, [0/0], 07:54:58, local 10.14.123.0/24, ubest/mbest: 1/0, attached *via 10.14.123.1, Vlan123, [0/0], 07:54:58, direct 10.14.123.1/32, ubest/mbest: 1/0, attached *via 10.14.123.1, Vlan123, [0/0], 07:54:58, local 10.14.124.0/24, ubest/mbest: 1/0, attached *via 10.14.124.1, Vlan124, [0/0], 07:54:58, direct 10.14.124.1/32, ubest/mbest: 1/0, attached *via 10.14.124.1, Vlan124, [0/0], 07:54:58, local 11.31.209.14/31, ubest/mbest: 1/0 *via 192.168.3.3%default, [200/0], 00:16:38, bgp-65160, internal, tag 65160, segid: 40003 tunnelid: 0xc0a80303 encap: VXLAN 11.31.209.18/31, ubest/mbest: 1/0 *via 192.168.3.4%default, [200/0], 00:16:38, bgp-65160, internal, tag 65160, segid: 40003 tunnelid: 0xc0a80304 encap: VXLAN 11.31.212.14/31, ubest/mbest: 1/0 *via 192.168.3.11%default, [200/0], 00:16:38, bgp-65160, internal, tag 65160, segid: 40003 tunnelid: 0xc0a8030b encap: VXLAN 11.31.212.18/31, ubest/mbest: 1/0 *via 192.168.3.12%default, [200/0], 00:16:38, bgp-65160, internal, tag 65160, segid: 40003 tunnelid: 0xc0a8030c encap: VXLAN 200.200.200.0/28, ubest/mbest: 2/0 *via 192.168.3.11%default, [200/0], 00:16:38, bgp-65160, internal, tag 65160, segid: 40003 tunnelid: 0xc0a8030b encap: VXLAN *via 192.168.3.12%default, [200/0], 00:16:38, bgp-65160, internal, tag 65160, segid: 40003 tunnelid: 0xc0a8030c encap: VXLAN
Shutdown or remove the interface nve 1.
Click on a version to see all relevant bugs
Cisco Integration
Learn more about where this data comes from
Bug Scrub Advisor
Streamline upgrades with automated vendor bug scrubs
BugZero Enterprise
Wish you caught this bug sooner? Get proactive today.