Need to get the approval from account team before disclosing the bug to the Customer.
{+} "ipp" service crashing ~160sec after 'no opflex-peer ' command line is executed. -- 2020 Jun 14 22:33:00 configure terminal ; ipp ; fabric 1 ; no opflex-peer 11.1.10.18 8009 (SUCCESS) 2020 Jun 14 22:33:10 configure terminal ; ipp ; fabric 1 ; no opflex-peer 11.4.0.24 8009 (SUCCESS) 2020 Jun 14 22:33:10.641 %CLIS-3-DATAXCHG: Error receiving message: Command timed out 2020 Jun 14 22:33:25 configure terminal ; ipp ; fabric 1 ; no opflex-peer 11.1.10.20 8009 (SUCCESS) 2020 Jun 14 22:33:49.505 %CLIS-3-DATAXCHG: Error receiving message: Command timed out 2020 Jun 14 22:33:49.505 vsh[805]: CLI-3-DATAXCHG: Error receiving message: General Error 2020 Jun 14 22:34:49.421 vsh[805]: CLI-3-DATAXCHG: Error receiving message: General Error 2020 Jun 14 22:34:49.421 %VSHD-5-VSHD_SYSLOG_CONFIG_I: Configured from vty by akhatri on 85.205.247.39@pts/12 2020 Jun 14 22:35:07.586 vsh[805]: CLI-3-DATAXCHG: Error receiving message: General Error 2020 Jun 14 22:36:04.944 %SYSMGR-2-SERVICE_CRASHED: Service "ipp" (PID 27540) hasn't caught signal 6 (core will be saved). 2020 Jun 14 22:36:17.329 vsh[805]: CLI-3-DATAXCHG: Error receiving message: General Error --
{+} Have opflex-peer configured and active (no shutdown) on IPP > Fabric config mode.
{+} In case there's need to remove an opflex peer, first shutdown the fabric, then remove the opflex-peer command line and restore the fabric: -- ipp fabric 1 shutdown no opflex-peer 8009 no shutdown ! --
{+} The crash is only seen when there are 'Error receiving' messages also. {+} Sysmgr will report that ipp service stopped replying heartbeats and will kill it: Service: ipp Description: Interconnect Policy Provisioning Executable: /isan/bin/ipp Started at Mon Nov 19 23:55:33 2018 (652124 us) Stopped at Sun Jun 14 01:39:13 2020 (328994 us) Uptime: 572 days 43 minutes 40 seconds Start type: SRV_OPTION_RESTART_STATELESS (23) Death reason: SYSMGR_DEATH_REASON_FAILURE_HEARTBEAT (9)
Click on a version to see all relevant bugs
Cisco Integration
Learn more about where this data comes from
Bug Scrub Advisor
Streamline upgrades with automated vendor bug scrubs
BugZero Enterprise
Wish you caught this bug sooner? Get proactive today.