OPERATIONAL DEFECT DATABASE
...


...

RP Alarm Major LED seen RED due to Canbus detected CPI failed upon LC removal. RP/0/RP0/CPU0:router#admin show led ============================================================= Location LED Name Mode Color ============================================================= 0/RP0 0/RP0-Fail LED WORKING OFF 0/RP0-ACO LED WORKING OFF 0/RP0-Alarm Minor LED WORKING OFF 0/RP0-Alarm Major LED WORKING RED 0/RP0-Alarm Critical LED WORKING OFF 0/RP0-FC Fault LED WORKING OFF 0/RP1 0/RP1-Fail LED WORKING OFF 0/RP1-ACO LED WORKING OFF 0/RP1-Alarm Minor LED WORKING OFF 0/RP1-Alarm Major LED WORKING RED 0/RP1-Alarm Critical LED WORKING OFF 0/RP1-FC Fault LED WORKING OFF
Canbus detected CPI failed upon LC removal. RP/0/RP0/CPU0:router#admin show alarms brief ------------------------------------------------------------------------------- Active Alarms ------------------------------------------------------------------------------- Location Severity Group Set time Description ------------------------------------------------------------------------------- 0/17 major controller 04/01/20 00:56:20 Canbus detected CPI failed RP/0/RP0/CPU0:router#show logging 0/RP0/ADMIN0:2020 Apr 1 02:56:20.340 : canbus_driver[4418]: %PLATFORM-CANB_SERVER-7-CBC_PRE_RESET_NOTIFICATION : Node 0/17 CBC-1, reset reason CPU_RESET_PLDREQ_HRESET (0x0c000000) 0/RP0/ADMIN0:2020 Apr 1 02:56:20.351 : shelf_mgr[4450]: %INFRA-SHELF_MGR-5-CARD_REMOVAL : Location: 0/17, Serial#: 0/RP0/ADMIN0:2020 Apr 1 02:56:20.454 : canbus_driver[4418]: %PLATFORM-CANB_SERVER-3-ALARM_INDICATION : Raise alarm from CBC1 in slot 0/17, alarm code CBC_ALRM_CPI_FAILED
Reloading the problem RP clears the alarm
Click on a version to see all relevant bugs
Cisco Integration
Learn more about where this data comes from
Bug Scrub Advisor
Streamline upgrades with automated vendor bug scrubs
BugZero Enterprise
Wish you caught this bug sooner? Get proactive today.