No Alarm is there in show controllers optics on port 0/0/2/1 with the power level -35.22 dBm while the other device has the LOW-RX-PWR on port 0/0/1/0 with the -30.45 dBm Power. RTR1#show controllers optics 0/0/2/1 Controller State: Down <<<<<<<<<< Transport Admin State: In Service Laser State: On LED State: Red Optics Status Optics Type: CFP2 DWDM DWDM carrier Info: C BAND, MSA ITU Channel=43, Frequency=194.00THz, Wavelength=1545.322nm Alarm Status: ------------- Detected Alarms: None <<<<<<<<<<<<< No Alarm LOS/LOL/Fault Status: Alarm Statistics: ------------- HIGH-RX-PWR = 0 LOW-RX-PWR = 35 HIGH-TX-PWR = 0 LOW-TX-PWR = 1 HIGH-LBC = 0 HIGH-DGD = 0 OOR-CD = 0 OSNR = 0 WVL-OOL = 0 MEA = 0 IMPROPER-REM = 0 TX-POWER-PROV-MISMATCH = 0 Laser Bias Current = 0.0 % Actual TX Power = -1.49 dBm RX Power = -35.22 dBm <<<<<<<<<<<< Power Level -35 RTR2#sh controllers optics 0/0/1/0 Controller State: Up <<<<<<<<<<< Transport Admin State: In Service Laser State: On LED State: Green Optics Status Optics Type: CFP2 DWDM DWDM carrier Info: C BAND, MSA ITU Channel=43, Frequency=194.00THz, Wavelength=1545.322nm Alarm Status: ------------- Detected Alarms: LOW-RX-PWR <<<<<<<<<<<<< Alarm detected LOS/LOL/Fault Status: Alarm Statistics: ------------- HIGH-RX-PWR = 0 LOW-RX-PWR = 617 <<<<<<<< Number of times HIGH-TX-PWR = 0 LOW-TX-PWR = 1 HIGH-LBC = 0 HIGH-DGD = 0 OOR-CD = 0 OSNR = 0 WVL-OOL = 0 MEA = 0 IMPROPER-REM = 0 TX-POWER-PROV-MISMATCH = 0 Laser Bias Current = 0.0 % Actual TX Power = -1.49 dBm RX Power = -30.45 dBm <<<<<<<<<<<<<< power level -30
Interface state stays UP with traffic and did not show any alarm in Alarm Status even with -35 Dbm power level
Use "show controller coherentDSP " and/or "show alarms" CLI to co-relate the alarms.
Click on a version to see all relevant bugs
Cisco Integration
Learn more about where this data comes from
Bug Scrub Advisor
Streamline upgrades with automated vendor bug scrubs
BugZero Enterprise
Wish you caught this bug sooner? Get proactive today.