Nexus 9500 switch running 7.0.3.I7.6 will udld errdisable recovery enabled will not show enabled int the output of 'show errdisable recovery'
Symptoms can be observed when 'errdisable recovery cause all' is globally configured and then 'show errdisable recover' command is ran to verify errdisable recovery status.
No known workaround
LABtestNEXUS(config)# sh mod Mod Ports Module-Type Model Status --- ----- ------------------------------------- --------------------- --------- 1 36 36x100G Ethernet Module N9K-X9736C-EX ok 2 52 48x10/25G + 4x40/100G Ethernet Module N9K-X97160YC-EX ok 22 0 Unknown Module powered-dn 24 0 16-slot Fabric Module N9K-C9516-FM-E ok 26 0 16-slot Fabric Module N9K-C9516-FM-E ok 27 0 Supervisor Module N9K-SUP-A+ active * 29 0 System Controller N9K-SC-A active 30 0 System Controller N9K-SC-A standby Mod Sw Hw Slot --- ---------------- ------ ---- 1 7.0(3)I7(6) 0.4160 LC1 2 7.0(3)I7(6) 0.1120 LC2 24 7.0(3)I7(6) 0.1150 FM4 26 7.0(3)I7(6) 0.1150 FM6 27 7.0(3)I7(6) 0.1150 SUP1 29 7.0(3)I7(6) 1.6 SC1 30 7.0(3)I7(6) 1.6 SC2 Mod MAC-Address(es) Serial-Num --- -------------------------------------- ---------- 1 00-6b-f1-bf-03-f0 to 00-6b-f1-bf-04-83 FOC204523FY 2 00-6b-f1-be-b3-60 to 00-6b-f1-be-b3-a3 FOC204004SC 24 NA FOC205143ZA 26 NA FOC205147ED 27 08-96-ad-a9-a8-5e to 08-96-ad-a9-a8-6f FOC21112AMV 29 NA FOC21453MEP 30 NA FOC21453M7Q Mod Online Diag Status --- ------------------ 1 Pass 2 Fail 24 Pass 26 Pass 27 Pass 29 Pass 30 Pass LABtestNEXUS# sh ver | i image NXOS image file is: bootflash:///nxos.7.0.3.I7.6.bin LABtestNEXUS# LABtestNEXUS# LABtestNEXUS# sh run | i errdisable errdisable recovery cause link-flap errdisable recovery cause udld errdisable recovery cause bpduguard errdisable recovery cause loopback errdisable recovery cause storm-control errdisable recovery cause security-violation errdisable recovery cause psecure-violation errdisable recovery cause vpc-peerlink errdisable recovery cause failed-port-state errdisable recovery cause dcbx-no-ack LABtestNEXUS# LABtestNEXUS# LABtestNEXUS# LABtestNEXUS# LABtestNEXUS# sh er rec ErrDisable Reason Timer Status ----------------- ------------ link-flap disabled udld disabled bpduguard disabled loopback disabled storm-ctrl disabled dhcp-rate-lim disabled arp-inspection disabled sec-violation enabled psec-violation enabled vpc-peerlink enabled port-state-failed enabled event-debug disabled event-debug1 disabled event-debug2 disabled event-debug3 disabled event-debug4 disabled ip-addr-conflict disabled ipqos-mgr-error disabled ethpm disabled ipqos-compat-failure disabled syserr based disabled CMM miscabling disabled md-mismatch disabled hw-res-exhaustion disabled reinit-no-flap disabled dcbx-error enabled vlan-membership-erro disabled pause-rate-limit disabled inline-power disabled unknown enum: disabled unknown enum: disabled unknown enum: disabled unknown enum: disabled unknown enum: disabled unknown enum: disabled unknown enum: disabled unknown enum: disabled Timer interval: 300