OPERATIONAL DEFECT DATABASE
...

...
Switch does not relay DHCP packets.
Nexus 92160YC-X switch's TCAM carvings for ing-l2-span-filter, ing-l3-span-filter and span are emptied and there is no more free space to assign TCAM the switch does not relay DHCP packets. Example output of affected configuration on TCAM: switch# show system internal access-list globals slot 1 ======= -------------------------------------------------------------------------------- ------ INSTANCE 0 TCAM Region Information: -------------------------------------------------------------------------------- ------ Ingress: -------- Region TID Base Size Width -------------------------------------------------------------------------------- ------ NAT 13 0 0 1 Ingress PACL 1 0 0 1 Ingress VACL 2 0 0 1 Ingress RACL 3 0 2816 1 Ingress L2 QOS 5 2816 512 1 Ingress L3/VLAN QOS 6 3328 256 1 Ingress SUP 7 3584 512 1 Ingress L2 SPAN ACL 8 0 0 1 << Ingress L3/VLAN SPAN ACL 9 0 0 1 << SPAN 12 0 0 1 << Size set to 0 -------------------------------------------------------------------------------- ----- Total configured size: 4096 Remaining free size: 0 << no remaining space Note: Ingress SUP region includes Redirect region
Reserve TCAM size for one of the three regions or set aside some free size of TCAM with the global configuration command: hardware access-list tcam region
this behavior was seen only on Nexus 92160YC-X and was tested on the following versions: nxos.9.2.3.bin nxos.7.0.3.I7.6.bin nxos.7.0.3.I7.5a.bin nxos.7.0.3.I7.3.bin nxos.7.0.3.I3.1.bin
Click on a version to see all relevant bugs
Cisco Integration
Learn more about where this data comes from
Bug Scrub Advisor
Streamline upgrades with automated vendor bug scrubs
BugZero Enterprise
Wish you caught this bug sooner? Get proactive today.