40G and 100G MultiLane Transceivers not populating proper DOM values. ASR903 / 15.6(2)SP1b QSFP-40G-ER4 Mar 28 2019 09:14:29.077 JST: %SFF8472-3-THRESHOLD_VIOLATION: Fo0/5/0: Tx power high alarm; Operating value: 8.0 dBm, Threshold value: 7.5 dBm. router#show hw-module subslot 0/5 transceiver 0 status The Transceiver in slot 0 subslot 5 port 0 is enabled. Module temperature = +47.507 C Transceiver Tx supply voltage = 3.2976 Volts Transceiver Tx power = 8.0 dBm (6.3887 mW) <<<<<< Transceiver Rx optical power = -7.4 dBm (0.1821 mW) Optical High Alarm High Warn Low Warn Low Alarm Transmit Power Threshold Threshold Threshold Threshold Port (dBm) (dBm) (dBm) (dBm) (dBm) --------- ----------------- ---------- --------- --------- --------- Fo0/5/1 7.8 7.5 4.5 -2.7 -6.7 Optical High Alarm High Warn Low Warn Low Alarm Receive Power Threshold Threshold Threshold Threshold Port (dBm) (dBm) (dBm) (dBm) (dBm) --------- ----------------- ---------- --------- --------- --------- Fo0/5/1 -8.8 -1.5 -4.5 -21.2 -25.2
QSFP-40G-ER4
no workaround
n/a
Cisco Integration
Learn more about where this data comes from
Bug Scrub Advisor
Streamline upgrades with automated vendor bug scrubs
BugZero Enterprise
Wish you caught this bug sooner? Get proactive today.