OPERATIONAL DEFECT DATABASE
...

...
LC/0/0/CPU0:Oct 3 23:28:54.940 EST: bfd_agent[123]: %L2-BFD-6-SESSION_STATE_DOWN : BFD session to neighbor 192.168.36.1 on interface TenGigE0/0/0/22 has gone down. Reason: Echo function failed RP/0/RSP0/CPU0:Oct 3 23:28:54.943 EST: BM-DISTRIB[1172]: %L2-BM-5-MBR_BFD_SESSION_DOWN : The BFD session on link TenGigE0/0/0/22 in Bundle-Ether360 is down due to the receipt of a Down SCN. The member will be removed from the active members of the bundle. RP/0/RSP0/CPU0:Oct 3 23:28:54.943 EST: BM-DISTRIB[1172]: %L2-BM-6-ACTIVE : TenGigE0/0/0/22 is no longer Active as part of Bundle-Ether360 (BFD state of this link is Down) LC/0/0/CPU0:Oct 3 23:28:54.945 EST: bfd_agent[123]: %L2-BFD-6-SESSION_DAMPENING_ON : Session to neighbor 192.168.36.1 on interface TenGigE0/0/0/22 entered Dampened state (initial: 16000 ms,secondary: 20000 ms,maximum: 600000 ms). LC/0/0/CPU0:Oct 3 23:28:55.239 EST: bfd_agent[123]: %L2-BFD-6-SESSION_STATE_DOWN : BFD session to neighbor 192.168.36.1 on interface TenGigE0/0/0/23 has gone down. Reason: Echo function failed LC/0/0/CPU0:Oct 3 23:28:55.240 EST: bfd_agent[123]: %L2-BFD-6-SESSION_DAMPENING_ON : Session to neighbor 192.168.36.1 on interface TenGigE0/0/0/23 entered Dampened state (initial: 16000 ms,secondary: 20000 ms,maximum: 600000 ms). RP/0/RSP0/CPU0:Oct 3 23:28:55.242 EST: BM-DISTRIB[1172]: %L2-BM-5-MBR_BFD_SESSION_DOWN : The BFD session on link TenGigE0/0/0/23 in Bundle-Ether360 is down due to the receipt of a Down SCN. The member will be removed from the active members of the bundle. RP/0/RSP0/CPU0:Oct 3 23:28:55.242 EST: BM-DISTRIB[1172]: %L2-BM-6-ACTIVE : TenGigE0/0/0/23 is no longer Active as part of Bundle-Ether360 (BFD state of this link is Down) LC/0/0/CPU0:Oct 3 23:28:55.465 EST: bfd_agent[123]: %L2-BFD-6-SESSION_STATE_DOWN : BFD session to neighbor 192.168.44.1 on interface TenGigE0/0/0/8 has gone down. Reason: Nbor signalled down LC/0/0/CPU0:Oct 3 23:28:55.466 EST: bfd_agent[123]: %L2-BFD-6-SESSION_STATE_DOWN : BFD session to neighbor 192.168.45.1 on interface TenGigE0/0/0/11 has gone down. Reason: Nbor signalled down RP/0/RSP0/CPU0:Oct 3 23:28:55.469 EST: BM-DISTRIB[1172]: %L2-BM-5-MBR_BFD_SESSION_DOWN : The BFD session on link TenGigE0/0/0/8 in Bundle-Ether440 is down due to the receipt of a Down SCN. The member will be removed from the active members of the bundle. RP/0/RSP0/CPU0:Oct 3 23:28:55.469 EST: BM-DISTRIB[1172]: %L2-BM-5-MBR_BFD_SESSION_DOWN : The BFD session on link TenGigE0/0/0/11 in Bundle-Ether450 is down due to the receipt of a Down SCN. The member will be removed from the active members of the bundle. RP/0/RSP0/CPU0:Oct 3 23:28:55.469 EST: BM-DISTRIB[1172]: %L2-BM-6-ACTIVE : TenGigE0/0/0/8 is no longer Active as part of Bundle-Ether440 (BFD state of this link is Down) RP/0/RSP0/CPU0:Oct 3 23:28:55.469 EST: BM-DISTRIB[1172]: %L2-BM-6-ACTIVE : TenGigE0/0/0/11 is no longer Active as part of Bundle-Ether450 (BFD state of this link is Down) LC/0/0/CPU0:Oct 3 23:28:57.295 EST: bfd_agent[123]: %L2-BFD-6-SESSION_DAMPENING_ON : Session to neighbor 192.168.44.1 on interface TenGigE0/0/0/8 entered Dampened state (initial: 16000 ms,secondary: 20000 ms,maximum: 600000 ms). LC/0/0/CPU0:Oct 3 23:28:57.295 EST: bfd_agent[123]: %L2-BFD-6-SESSION_DAMPENING_ON : Session to neighbor 192.168.45.1 on interface TenGigE0/0/0/11 entered Dampened state (initial: 16000 ms,secondary: 20000 ms,maximum: 600000 ms). LC/0/0/CPU0:Oct 3 23:29:10.260 EST: bfd_agent[123]: %L2-BFD-6-SESSION_DAMPENING_OFF : Session to neighbor 192.168.36.1 on interface TenGigE0/0/0/22 moved out of Dampened state. LC/0/0/CPU0:Oct 3 23:29:10.260 EST: bfd_agent[123]: %L2-BFD-6-SESSION_DAMPENING_OFF : Session to neighbor 192.168.36.1 on interface TenGigE0/0/0/23 moved out of Dampened state. LC/0/0/CPU0:Oct 3 23:29:11.645 EST: bfd_agent[123]: %L2-BFD-6-SESSION_DAMPENING_OFF : Session to neighbor 192.168.44.1 on interface TenGigE0/0/0/8 moved out of Dampened state. LC/0/0/CPU0:Oct 3 23:29:11.645 EST: bfd_agent[123]: %L2-BFD-6-SESSION_DAMPENING_OFF : Session to neighbor 192.168.45.1 on interface TenGigE0/0/0/11 moved out of Dampened state. LC/0/0/CPU0:Oct 3 23:29:17.272 EST: bfd_agent[123]: %L2-BFD-6-SESSION_STATE_UP : BFD session to neighbor 192.168.36.1 on interface TenGigE0/0/0/22 is up RP/0/RSP0/CPU0:Oct 3 23:29:17.275 EST: BM-DISTRIB[1172]: %L2-BM-6-MBR_BFD_SESSION_UP : The BFD session on link TenGigE0/0/0/22 in Bundle-Ether360 has gone UP.
10G Typhoon on either end of link
None
Click on a version to see all relevant bugs
Cisco Integration
Learn more about where this data comes from
Bug Scrub Advisor
Streamline upgrades with automated vendor bug scrubs
BugZero Enterprise
Wish you caught this bug sooner? Get proactive today.