When there is PSU inserted into Cat3850/Cat3650/Cat9300 switch that does not have power cable connected to a power source the incorrect PSU information is shown in the show environment power all output
Cat3850/Cat3650/Cat9300 switch PSU inserted into the switch Power cable not connected to power source
connect the PSU to a working power source if the PSU needs to be installed in the switch remove the PSU from the switch if it is not needed
The sample output showing incorrect information for PSU bay B of switch 4 Cat3850#show environment power all SW PID Serial# Status Sys Pwr PoE Pwr Watts -- ------------------ ---------- --------------- ------- ------- ----- 1A Not Present 1B PWR-C1-715WAC LIT172xxxxx OK Good Good 715 2A Not Present 2B PWR-C1-715WAC DCB183xxxxx OK Good Good 715 3A PWR-C1-715WAC LIT193xxxxx OK Good Good 715 3B Not Present 4A Not Present 4B Unknown Unknown No Input Power Bad Bad 235