Using different port speeds on port pairs causes the even number port always goes hardware disabled. eth 1/1 as 40g and 1/2 as 10. fab5-leaf7#- Eth1/1 0 eth trunk up out-of-service 40G(D) -- Eth1/2 0 eth trunk down hw-disabled 10G(D) -- eth1/1 as 10g and 1/2 as 40g fab5-leaf7# Eth1/1 0 eth trunk up notconnect 10G(D) -- Eth1/2 0 eth trunk down hw-disabled 40G(D) --
When using different speeds on port pairs on the 93180LC-EX then the even number port will always be hw-disabled. This happens before any configuration is applied to the ports in ACI.
None. This is a hardware limitation of the 93180LC-EX.
N/A