Cat3850 stack logging onboard(OBFL) config disappear after switchover. --------------------------------- BGL.T.19-3850-2#sh run | in onboard hw-switch switch 1 logging onboard message hw-switch switch 2 logging onboard message hw-switch switch 3 logging onboard message BGL.T.19-3850-2# BGL.T.19-3850-2# BGL.T.19-3850-2#sh switch Switch/Stack Mac Address : 2834.a2fc.cf80 - Local Mac Address Mac persistency wait time: Indefinite H/W Current Switch# Role Mac Address Priority Version State ------------------------------------------------------------------------------------- *1 Active 2834.a2fc.cf80 14 V00 Ready 2 Member c07b.bc35.c500 15 V02 Ready 3 Standby c07b.bc94.c580 5 V02 Ready BGL.T.19-3850-2#reload slot 1 Proceed with reload? [confirm] BGL.T.19-3850-2# BGL.T.19-3850-2 console is now available Press RETURN to get started. BGL.T.19-3850-2> BGL.T.19-3850-2>en BGL.T.19-3850-2# BGL.T.19-3850-2#sh switch Switch/Stack Mac Address : 2834.a2fc.cf80 - Foreign Mac Address Mac persistency wait time: Indefinite H/W Current Switch# Role Mac Address Priority Version State ------------------------------------------------------------------------------------- 1 Member 0000.0000.0000 0 V00 Removed 2 Member c07b.bc35.c500 15 V02 Ready *3 Active c07b.bc94.c580 5 V02 Ready BGL.T.19-3850-2# BGL.T.19-3850-2# BGL.T.19-3850-2#sh run | in onboard BGL.T.19-3850-2#
looks like this issue not occur in 2 switches stack.
NA