Multiple sensor of NC6-10X100G-M-K sometimes report a Minor Lo voltage. The value is marked with a ! on the admin show env voltage display. sysadmin-vm:0_RP0# show environment voltages ================================================================================ Location Sensor Value Crit Minor Minor Crit (mV) (Lo) (Lo) (Hi) (Hi) ================================================================================ (snip) 0/1 VRM12 In 11437 9270 9530 14190 14520 VRM12 VCC Out 886 450 460 1630 1672 VRM12 VSA Out 865 810 830 970 990 (snip) ! Vctrl0-VP10P8 9437 9270 9530 14190 14520 <<<<<<<<<<<< ! VP3P3 MB 9425 9270 9530 14190 14520 <<<<<<<<<<<< ! VP1P8 MB 9400 9270 9530 14190 14520 <<<<<<<<<<<< ! VP1P0 MB 9375 9270 9530 14190 14520 <<<<<<<<<<<< ! VP0P9 MB 9375 9270 9530 14190 14520 <<<<<<<<<<<< ! VP0P9_GN MB 9375 9270 9530 14190 14520 <<<<<<<<<<<< ! VP1P5_DDR3 MB 9400 9270 9530 14190 14520 <<<<<<<<<<<< ! VP1P05 MB 9400 9270 9530 14190 14520 <<<<<<<<<<<< ! CPU VCC 9375 9270 9530 14190 14520 <<<<<<<<<<<< ! VP2P5 MB 9400 9270 9530 14190 14520 <<<<<<<<<<<< (snip) ! Slice 0 PITA VP1P0 9425 9270 9530 14190 14520 <<<<<<<<<<<< (snip) ! Slice 0 PITA VP0P9 9400 9270 9530 14190 14520 <<<<<<<<<<<< ! Slice 1 PITA VP1P0 9400 9270 9530 14190 14520 <<<<<<<<<<<< (snip) ! Slice 1 PITA VP0P9 9400 9270 9530 14190 14520 <<<<<<<<<<<<
It may happen when the "show env voltage " command is executed on Admin VM.
There is no workaround.
These are normal values, there is no traffic impact.