N2K-C2348UPQ-10GE
FEX connected to a Nexus 5K/6K parent might not come up at all or intermittently fail to come up after reloads. A show interface on the parent switch will indicate the FEX fabric interfaces to be in
SDP timeout/SFP Mismatch
state
N6K(config-if-range)# show int eth 1/21-28 brief
--------------------------------------------------------------------------------
Ethernet VLAN Type Mode Status Reason Speed PortInterface Ch #
--------------------------------------------------------------------------------
Eth1/21 1 eth fabric down SDP timeout/SFP Mismatch 10G(D) --
Eth1/22 1 eth fabric down SDP timeout/SFP Mismatch 10G(D) --
Eth1/23 1 eth fabric down SDP timeout/SFP Mismatch 10G(D) --
Eth1/24 1 eth fabric down SDP timeout/SFP Mismatch 10G(D) --
Eth1/25 1 eth fabric down SDP timeout/SFP Mismatch 10G(D) --
Eth1/26 1 eth fabric down SDP timeout/SFP Mismatch 10G(D) --
Eth1/27 1 eth fabric down SDP timeout/SFP Mismatch 10G(D) --
Eth1/28 1 eth fabric down SDP timeout/SFP Mismatch 10G(D) --
N2K-C2348UPQ-10GE
FEX connected to a Nexus 5K/6K. This issue is resolved in NX-OS
Workaround
Upgrade the parent N5K/6K to NX-OS
7.1(1)N1(1)
and power cycle the the FEX few times with fabric connection to the parent in place. If the FEX does not come online contact TAC
Further Problem Description