received the following error messages on installing the packages after the Box was USB booted to the new 5.2.1 Build and both RP0 and RP1 were running the new code. RP/0/RP0/CPU0:ios# RP/0/RP0/CPU0:ios#install add source harddisk:/5.2.1/ ncs6k-mgbl.pkg-5.2.1 ncs6k-mpls.pkg-5.2.1 ncs6k-k9sec.pkg-5.2.1 Mon Sep 29 23:11:22.694 UTC Sep 29 23:11:24 Install operation 1 started by admin: install add source harddisk:/5.2.1/ ncs6k-mgbl.pkg-5.2.1 ncs6k-mpls.pkg-5.2.1 ncs6k-k9sec.pkg-5.2.1 Sep 29 23:11:25 Install operation will continue in the background RP/0/RP0/CPU0:ios#Sep 29 23:11:32 Install operation 1 finished successfully 0/1/ADMIN0:Sep 29 23:11:43.128 : inst_agent[1832]: %INFRA-INSTAGENT-2-SELF_TEST_FAILED : This node has failed verification of its installed software base. A new disk will be prepared. 0/0/ADMIN0:Sep 29 23:11:43.127 : inst_agent[1818]: %INFRA-INSTAGENT-2-SELF_TEST_FAILED : This node has failed verification of its installed software base. A new disk will be prepared. LC/0/1/CPU0:Sep 29 23:11:36.034 : npu_driver[132]: %L2-NPU-3-ERROR_MSG : Received node down notification proceed to bringdown all interfaces LC/0/0/CPU0:Sep 29 23:11:36.070 : npu_driver[143]: %L2-NPU-3-ERROR_MSG : Received node down notification proceed to bringdown all interfaces 0/0/ADMIN0:Sep 29 23:11:52.002 : inst_agent[1818]: %INFRA-INSTAGENT-2-SELF_TEST_FAILED : This node has failed verification of its installed software base. A new disk will be prepared. 0/1/ADMIN0:Sep 29 23:11:52.005 : inst_agent[1832]: %INFRA-INSTAGENT-2-SELF_TEST_FAILED : This node has failed verification of its installed software base. A new disk will be prepared. 0/RP0/ADMIN0:Sep 29 23:11:54.009 : shelf_mgr[1942]: %INFRA-SHELF_MGR-4-CARD_RELOAD : Reloading card 0/1 0/RP0/ADMIN0:Sep 29 23:11:54.033 : shelf_mgr[1942]: %INFRA-SHELF_MGR-4-CARD_RELOAD : Reloading card 0/1 0/RP0/ADMIN0:Sep 29 23:11:54.035 : shelf_mgr[1942]: %INFRA-SHELF_MGR-4-CARD_RELOAD : Reloading card 0/0 0/RP0/ADMIN0:Sep 29 23:11:54.035 : shelf_mgr[1942]: %INFRA-SHELF_MGR-4-CARD_RELOAD : Reloading card 0/0 RP/0/RP0/CPU0:ios# Both the line cards booted up after sometime but now I see the Admin state as DOWN for the LCs (even though the NPUs show as UP). RP/0/RP0/CPU0:ios#show platform Mon Sep 29 23:41:39.916 UTC Node name Node type Node state Admin state Config state ----------------------------------------------------------------------------------- 0/0 NC6-10X100G-L-K OPERATIONAL DOWN NSHUT 0/0/NPU0 Slice UP UP 0/0/NPU1 Slice UP UP 0/0/NPU2 Slice UP UP 0/0/NPU3 Slice UP UP 0/0/NPU4 Slice UP UP 0/1 NC6-10X100G-L-K OPERATIONAL DOWN NSHUT 0/1/NPU0 Slice UP UP 0/1/NPU1 Slice UP UP 0/1/NPU2 Slice UP UP 0/1/NPU3 Slice UP UP 0/1/NPU4 Slice UP UP 0/RP0 NC6-RP OPERATIONAL UP NSHUT 0/RP1 NC6-RP OPERATIONAL UP NSHUT 0/FC0 NC6-FC OPERATIONAL UP NSHUT 0/FC1 NC6-FC OPERATIONAL UP NSHUT 0/FC2 NC6-FC OPERATIONAL UP NSHUT 0/FC4 NC6-FC OPERATIONAL UP NSHUT 0/FC5 NC6-FC OPERATIONAL UP NSHUT 0/FT0 NC6-FANTRAY OPERATIONAL UP NSHUT 0/FT1 NC6-FANTRAY OPERATIONAL UP NSHUT 0/PT0 NCS-AC-PWRTRAY OPERATIONAL UP NSHUT 0/PT1 NCS-AC-PWRTRAY OPERATIONAL UP NSHUT 0/PT2 NCS-AC-PWRTRAY OPERATIONAL UP NSHUT 0/PT3 NCS-AC-PWRTRAY OPERATIONAL UP NSHUT RP/0/RP0/CPU0:ios#
The box was USB Booted to 5.2.1
None.
Click on a version to see all relevant bugs
Cisco Integration
Learn more about where this data comes from
Bug Scrub Advisor
Streamline upgrades with automated vendor bug scrubs
BugZero Enterprise
Wish you caught this bug sooner? Get proactive today.