EPLD upgrade may fail on module N7K-M148GS-11L: switch# install all epld bootflash:n7000-s2-epld.6.2.2.img Retrieving EPLD versions... Please wait. Images will be upgraded according to following table: Module Type EPLD Running-Version New-Version Upg-Required ------ ---- ------------- --------------- ----------- ------------ X LC Power Manager 4.008 4.008 No X LC IO 1.006 1.006 No X LC Forwarding Engine 2.008 2.009 Yes X LC SFP 1.004 1.004 No The above modules require upgrade. Do you want to continue (y/n) ? [n] y The switch will reload after the upgrade process if you choose to upgrade the Active Supervisor. Do you want to upgrade the Active Supervisor also? [n] Y Proceeding to upgrade Modules. Starting Module X EPLD Upgrade 2 EPLD upgrade failed. Exiting.. Failure reason: File access error while upgrading the FPGA. (Error Number : 5) switch# show install epld status 2) Module X upgraded on Mon Oct 14 19:36:09 2013 (171801 us) EPLD Install Image: EPLD image file 6.2.2 built on Wed Aug 21 23:39:11 2013 Status: EPLD Upgrade failed Reason: File access error (Error Number : 5)
This issue happens only under this conditions: *** 'install all epld bootflash:n7000-s2-epld.6.2.2.img' was used; *** Hardware version of N7K-M148GS-11L is 2.0 or all above.
To finish upgrade, please use 'install module X epld' command.