Symptoms
NSX-T 3.2.0/3.2.0.1Edge VM auto deployed from the UIAn open alarm is present for Edge vSphere Location MismatchThis alarm can be triggered by vMotion of an EdgeThis alarm maybe triggered regardless of whether a specific host was selected at deployment time or not
Cause
NSX-T compares the intent configuration of the Edge with the realized configuration of the Edge to ensure they match.This alarm incorrectly considered the host location when making this evaluation.NSX-T Data Center 3.2.1 removed the host location from the location mismatch evaluation.
Resolution
This issue is resolved in NSX-T Data Center 3.2.1 and above.
Workaround
Workaround optionsRedeploy the Edge from the UI, note this can result in traffic disruptionorRefresh API call this does not cause any traffic disruption