1. When the SRM certificate expires, the plugin can automatically unregister itself from vCenter. 2. Option to reconfigure is no longer available in SRM VAMI, instead you will see Configure (Just like a new install)3. You won’t be able to register the appliance to vCenter4. You won’t find any log traces of SRM unregistered in the drconfigui.log / dr.logLaunching SRM from vCenter displays the messages : ERRORServer for guid '28dc11f4-a6e4-4b60-83a9-c5bc2aa58d8d' not found, but pair server(s) exist: [PairSetupImpl {_server = SrmServerImpl { _guid = 1bac4759-1880-4da5-9a62-7cae158647d0 _url = https://10.X.X.X:443/drserver/vcdr/vmomi/sdk }_pairServerGuid = 28dc11f4-a6e4-4b60-83a9-c5bc2aa58d8d_pairLsppUrl = https://vcenter.prod.local:443/lookupservice/sdk_pairLsppsThumbprint = 18:96:CF:51:5B:B0:D9:B9:4A:60:19:A3:FB:5E:7C:2A:5D:FE:22:00}]Operation ID: 7093d2c9-156d-418b-a6c2-51774d57e91e8/14/20, 5:15:30 PM +0200ERRORUnable to retrieve Site Recovery Manager summary data.Server with UUID '28dc11f4-a6e4-4b60-83a9-c5bc2aa58d8d' not found.Operation ID: 3e83de0f-e037-4a69-955a-6c2a03923ef38/14/20, 5:15:30 PM +02002020-08-14 14:22:21,713 [srm-reactive-thread-4] WARN com.vmware.dr.configservice.taskMonitor.ConfigureTaskHandler 847dcbd6-6d30-4fb4-9e7d-b91cc5d889c6 getConfigureTaskProgress - Task finished with error!(vmodl.fault.SystemError) { faultCause = null, faultMessage = null, reason = 22ConfigurationException Failed to configure DR server with the Infrastructure Node services. Reason: Fault cause: vmodl.fault.InvalidArgumentWhen you try to configure SRM appliance to register with vCenter, it throws the error :ERROROperation FailedA general system error occurred: 22ConfigurationException Failed to configure DR server with the Infrastructure Node services. Reason: Fault cause: vmodl.fault.InvalidArgumentExit code: 61[context]zKq7AVECAAQAAL+xzQAOZHJjb25maWcAAIvFGGxpYnZtYWNvcmUuc28AAcicC2RyLWNvbmZpZ3VyYXRvcgABIvILAVWNBgFrmQYBG6AGARcCBwHb7QUB3EsHAFGeKQD/uikAGjQ3ApV0AGxpYnB0aHJlYWQuc28uMAADbwIPbGliYy5zby42AA==[/context][backtrace begin] product: VMware vCenter Site Recovery Manager, version: 8.2.0, build: build-13480383, tag: drconfig, cpu: x86_64, os: linux, buildType: releasebacktrace[03] libvmacore.so[0x0018C58B]: Vmacore::Throwable::Throwable(std::string&&)backtrace[04] dr-configurator[0x000B9CC8]backtrace[05] dr-configurator[0x000BF222]backtrace[06] dr-configurator[0x00068D55]backtrace[07] dr-configurator[0x0006996B]backtrace[08] dr-configurator[0x0006A01B]backtrace[09] dr-configurator[0x00070217]backtrace[10] dr-configurator[0x0005EDDB]backtrace[11] dr-configurator[0x00074BDC]backtrace[12] libvmacore.so[0x00299E51]backtrace[13] libvmacore.so[0x0029BAFF]backtrace[14] libvmacore.so[0x0037341A]backtrace[15] libpthread.so.0[0x00007495]backtrace[16] libc.so.6[0x000F026F][backtrace end]Caused by:(vmodl.fault.InvalidArgument) faultCause = (vmodl.MethodFault) null, faultMessage = <unset>, invalidProperty = "Invalid certificate" msg = "Received SOAP response fault from [<cs p:00007f766c00e960, TCP:rdc1vc01v.za.sbicdirectory.com:443>]: create"[context]zKq7AVECAAQAAL+xzQAUZHJjb25maWcAAIvFGGxpYnZtYWNvcmUuc28AAb6gDmxpYnZtb21pLnNvAAEBhx4BatQNAYwJEgGDDhICAzQGbGliZHItdm1vbWkuc28AATIrFAHGKBQDbVkCbGlibGtwLXR5cGVzLnNvAAQPjAxkci1jb25maWd1cmF0b3IABGzfDAQ96QsEVY0GBGuZBgQboAYEFwIHBNvtBQTcSwcAUZ4p[/context][backtrace begin] product: VMware vCenter Site Recovery Manager, version: 8.2.0, build: build-13480383, tag: drconfig, cpu: x86_64, os: linux, buildType: releasebacktrace[03] libvmacore.so[0x0018C58B]: Vmacore::Throwable::Throwable(std::string&&)backtrace[04] libvmomi.so[0x000EA0BE]backtrace[05] libvmomi.so[0x001E8701]: Vmomi::Fault::InvalidArgument::ThrowInternal()backtrace[06] libvmomi.so[0x000DD46A]backtrace[07] libvmomi.so[0x0012098C]backtrace[08] libvmomi.so[0x00120E83]backtrace[09] libdr-vmomi.so[0x00063403]backtrace[10] libvmomi.so[0x00142B32]: Vmomi::StubImpl::_Invoke_Task(Vmomi::ManagedMethod*, std::vector<Vmacore::Ref<Vmomi::Any>, std::allocator<Vmacore::Ref<Vmomi::Any> > >&, Vmacore::Ref<Vmomi::Any>&)backtrace[11] libvmomi.so[0x001428C6]: Vmomi::StubImpl::_Invoke_Task(Vmomi::ManagedMethod*, std::vector<Vmacore::Ref<Vmomi::Any>, std::allocator<Vmacore::Ref<Vmomi::Any> > >&)backtrace[12] liblkp-types.so[0x0002596D]: Lookup::ServiceRegistrationStub::Create(std::string const&, Lookup::ServiceRegistration::CreateSpec*)backtrace[13] dr-configurator[0x000C8C0F]backtrace[14] dr-configurator[0x000CDF6C]backtrace[15] dr-configurator[0x000BE93D]backtrace[16] dr-configurator[0x00068D55]backtrace[17] dr-configurator[0x0006996B]backtrace[18] dr-configurator[0x0006A01B]backtrace[19] dr-configurator[0x00070217]backtrace[20] dr-configurator[0x0005EDDB]backtrace[21] dr-configurator[0x00074BDC]backtrace[22] libvmacore.so[0x00299E51][backtrace end]Operation ID: b01aa8a2-9a27-49c7-b133-ea2962451c3c
SRM certificate has expired
1. Login to SRM VAMI2. Click on the Access tab and click on CHANGE to renew the certificate3. Register SRM with vCenterChange the Site Recovery Manager Appliance Certificate