Symptoms
The ESXi 6.x host gets disconnected from vCenter ServerThe host is running on Dell hardware It cannot connect the ESXi 6.x host to vCenter ServerIt cannot connect to the ESXi 6.x host using the Host UI clientThe /var/log/hostd.log file indicates that the host is out of spaceIn vmkernel.log similar entries will be shown
2019-05-08T20:57:07.588Z: [VisorfsCorrelator] 201984788713us: [vob.visorfs.ramdisk.inodetable.full] Cannot create file /etc/vmware/esx.conf.LOCK for process vsanSoapServer because the inode table of its ramdisk (etc) is full.
2019-05-08T20:57:07.926Z: [VisorfsCorrelator] 201985127158us: [vob.visorfs.ramdisk.inodetable.full] Cannot create file /etc/cim/dell/srvadmin/iSM/ini/ttttttttttttt6e4qSO for process sfcb-dcism because the inode table of its ramdisk (etc) is full.
2019-05-08T20:57:07.927Z: [VisorfsCorrelator] 201992965228us: [esx.problem.visorfs.ramdisk.inodetable.full] The file table of the ramdisk 'etc' is full. As a result, the file /etc/cim/dell/srvadmin/iSM/ini/ttttttttttttt6e4qSO could not be created by the application 'sfcb-dcism'.
2019-05-08T20:57:07.927Z: [VisorfsCorrelator] 201985127663us: [vob.visorfs.ramdisk.inodetable.full] Cannot create file /etc/cim/dell/srvadmin/iSM/ini/ttttttttttttteLupwd for process sfcb-dcism because the inode table of its ramdisk (etc) is full.
2019-05-08T20:57:07.927Z: [VisorfsCorrelator] 201992965610us: [esx.problem.visorfs.ramdisk.inodetable.full] The file table of the ramdisk 'etc' is full. As a result, the file /etc/cim/dell/srvadmin/iSM/ini/ttttttttttttteLupwd could not be created by the application 'sfcb-dcism'Note:The preceding log excerpts are only examples.Date,time and environmental variables may vary depending on your environment
Cause
This issue occurs by the hardware monitoring service (dcism) that populates the /etc/cim/dell/srvadmin/iSM/ini directory.
Resolution
Engage with DellEMC support for a resolution with dcism vib.
Workaround
To workaround this issue:1. Connect to the ESXi host using SSH.2. Run this command to stop the dcism service: /etc/init.d/dcism-netmon-watchdog stop3. To ensure that the dcism does not start upon reboot chkconfig dcism-netmon-watchdog off4. Manually delete the files in the Check /etc/cim/dell/srvadmin/iSM/ini directory to free inodes. Such as tttttttttttttSQfKaqttttttttttttt8Rcadp5.Connect the ESXi back to vCenter if host does not come back into vCenter a reboot is required.