Container creation fails. Log snippet for reference.2018-12-05T20:28:46.137Z 37f52426-7afa-4226-b109-60293ad8ce19 NSX 11471 - [nsx@6876 comp="nsx-container-node" subcomp="nsx_node_agent" level="INFO"] oslo.privsep.daemon privsep process running with capabilities (eff/prm/inh): CAP_DAC_OVERRIDE|CAP_DAC_READ_SEARCH|CAP_NET_ADMIN|CAP_SYS_ADMIN|CAP_SYS_PTRACE/CAP_DAC_OVERRIDE|CAP_DAC_READ_SEARCH|CAP_NET_ADMIN|CAP_SYS_ADMIN|CAP_SYS_PTRACE/none1 2018-12-05T20:28:46.137Z 37f52426-7afa-4226-b109-60293ad8ce19 NSX 11471 - [nsx@6876 comp="nsx-container-node" subcomp="nsx_node_agent" level="INFO"] oslo.privsep.daemon privsep daemon running as pid 114711 2018-12-05T20:28:46.256Z 37f52426-7afa-4226-b109-60293ad8ce19 NSX 11443 - [nsx@6876 comp="nsx-container-node" subcomp="nsx_node_agent" level="INFO"] nsx_ujo.agent.agent Created veth pair nsx_agent_outer, nsx_agent_inner1 2018-12-05T20:28:46.465Z 37f52426-7afa-4226-b109-60293ad8ce19 NSX 11443 - [nsx@6876 comp="nsx-container-node" subcomp="nsx_node_agent" level="INFO"] nsx_ujo.agent.agent Configured interface nsx_agent_inner with IP 169.254.1.0/31, MAC 00:50:56:a5:87:761 2018-12-05T20:28:46.480Z 37f52426-7afa-4226-b109-60293ad8ce19 NSX 11443 - [nsx@6876 comp="nsx-container-node" subcomp="nsx_node_agent" level="INFO"] nsx_ujo.agent.agent Added OVS port nsx_agent_outer with vlan 40941 2018-12-05T20:28:46.520Z 37f52426-7afa-4226-b109-60293ad8ce19 NSX 11443 - [nsx@6876 comp="nsx-container-node" subcomp="nsx_node_agent" level="INFO"] nsx_ujo.agent.nsxrpc_client Listening NSX RPC connection...1 2018-12-05T20:28:46.521Z 37f52426-7afa-4226-b109-60293ad8ce19 NSX 11443 - [nsx@6876 comp="nsx-container-node" subcomp="nsx_node_agent" level="INFO"] cli.server.container_cli_server Starting node_agent CLI server1 2018-12-05T20:28:46.532Z 37f52426-7afa-4226-b109-60293ad8ce19 NSX 11443 - [nsx@6876 comp="nsx-container-node" subcomp="nsx_node_agent" level="INFO"] nsx_ujo.agent.cni_watcher CNI socket is listening...1 2018-12-05T20:39:05.068Z 37f52426-7afa-4226-b109-60293ad8ce19 NSX 11443 - [nsx@6876 comp="nsx-container-node" subcomp="nsx_node_agent" level="ERROR" errorCode="NCP01004"] nsx_ujo.agent.cni_watcher Unable to retrieve network info for container nsx.kube-system.kube-dns-6b697fcdbd-fb4tg, network interface for it will not be configured1 2018-12-05T20:39:06.073Z 37f52426-7afa-4226-b109-60293ad8ce19 NSX 11443 - [nsx@6876 comp="nsx-container-node" subcomp="nsx_node_agent" level="INFO"] nsx_ujo.agent.cni_watcher Failed to find OVS port for container 3497dd0a78a264bf97e4de52a88ce6e57158db92b92107f0abcdfce975c1e407: __init__() takes exactly 1 argument (2 given)1 2018-12-05T20:44:05.328Z 37f52426-7afa-4226-b109-60293ad8ce19 NSX 11443 - [nsx@6876 comp="nsx-container-node" subcomp="nsx_node_agent" level="ERROR" errorCode="NCP01004"] nsx_ujo.agent.cni_watcher Unable to retrieve network info for container nsx.kube-system.kube-dns-6b697fcdbd-fb4tg, network interface for it will not be configured1 2018-12-05T20:44:06.331Z 37f52426-7afa-4226-b109-60293ad8ce19 NSX 11443 - [nsx@6876 comp="nsx-container-node" subcomp="nsx_node_agent" level="INFO"] nsx_ujo.agent.cni_watcher Failed to find OVS port for container f2226c12e3786a35e180f669159e1c48dbf44981c7c558b78b8f25da2e8dd74f: __init__() takes exactly 1 argument (2 given)1 2018-12-05T20:49:05.606Z 37f52426-7afa-4226-b109-60293ad8ce19 NSX 11443 - [nsx@6876 comp="nsx-container-node" subcomp="nsx_node_agent" level="ERROR" errorCode="NCP01004"] nsx_ujo.agent.cni_watcher Unable to retrieve network info for container nsx.kube-system.kube-dns-6b697fcdbd-fb4tg, network interface for it will not be conf
Purpose is to overcome container creation failure due to HyperBus interface vmk50 not being present on ESXI.
Container is not created because the HyperBus interface vmk50 might be missing on vSphere ESXi.
None
Upgrade to NSX-T 2.3 and post that removed and added back the Fabric nodes or use the below workaround.Issue 1998217: HyperBus interface vmk50 might be missing on vSphere ESXi causing container creation failure Container is not created because the HyperBus interface vmk50 might be missing on vSphere ESXi. Workaround: Complete the following steps. Retrieve the vmk50 port ID using CLI on vSphere ESXi net-dvs | grep vmk50 -C 10Create the vmk50 interface on vSphere ESXi. esxcli network ip interface add -P <port-id from step-1> -s DvsPortset-0 -i vmk50 -N hyperbusAssign an IP address to the vmk50 interface. esxcfg-vmknic -i 169.254.1.1 -n 255.255.0.0 -s DvsPortset-0 -v <port-id from step-1> -N hyperbus
Issue 1998217: HyperBus interface vmk50 might be missing on vSphere ESXi causing container creation failure Container is not created because the HyperBus interface vmk50 might be missing on vSphere ESXi. Workaround: Complete the following steps. Retrieve the vmk50 port ID using CLI on vSphere ESXi net-dvs | grep vmk50 -C 10Create the vmk50 interface on vSphere ESXi. esxcli network ip interface add -P <port-id from step-1> -s DvsPortset-0 -i vmk50 -N hyperbusAssign an IP address to the vmk50 interface. esxcfg-vmknic -i 169.254.1.1 -n 255.255.0.0 -s DvsPortset-0 -v <port-id from step-1> -N hyperbus