[root@vmserver3:~] esxcfg-scsidevs -c Device UID Device Type Console Device Size Multipath PluginDisplay Name naa.6000d310041df2000000000000000005 Direct-Access /vmfs/devices/disks/naa.6000d310041df2000000000000000005 0MB NMP VMFS5 naa.6000d310041df2000000000000000007 Direct-Access /vmfs/devices/disks/naa.6000d310041df2000000000000000007 0MB NMP VMFS02 naa.6000d310041df2000000000000000009 Direct-Access /vmfs/devices/disks/naa.6000d310041df2000000000000000009 0MB NMP VMFS41 naa.6000d310041df200000000000000000a Direct-Access /vmfs/devices/disks/naa.6000d310041df200000000000000000a 1048576MB NMP VMFS6 naa.6000d310041df200000000000000000b Direct-Access /vmfs/devices/disks/naa.6000d310041df200000000000000000b 0MB NMP VMFS7 ### Devices are visible but size is shown as 0MB sas.5d0946606ea42c00-sas.5000d310041df21e-naa.6000d310041df200000000000000000b: Runtime Name: vmhba4:C0:T1:L7 Device: naa.6000d310041df200000000000000000b Device Display Name: VMFS7 Group State: standby Array Priority: 0 Storage Array Type Path Config: {TPG_id=61470,TPG_state=STBY,RTP_id=30,RTP_health=UP} Path Selection Policy Path Config: {current path; rank: 0} ### Standby Path is used for the current path naa.6000d310041df200000000000000000b : VMFS7 vmhba4:C0:T1:L7 LUN:7 state:standby sas Adapter: 5d0946606ea42c00 Target: 5000d310041df21e naa.6000d310041df200000000000000000c : VMLOG01 vmhba4:C0:T1:L8 LUN:8 state:active sas Adapter: 5d0946606ea42c00 Target: 5000d310041df21e ### In NMP path list host shows only one path for the device 2019-01-25T21:59:54.421Z cpu7:66233)WARNING: NMP: nmpCompleteRetryForPath:387: Logical device "naa.6000d310041df200000000000000000b": awaiting fast path state update before retrying failed command again... 2019-01-25T21:59:55.421Z cpu17:65820)WARNING: NMP: nmp_RegisterDeviceEvents:923: Could not register events 0x180 on device "naa.6000d310041df200000000000000000b", Status: Not found. Event Registration will be retried on next path eval. 2019-01-25T21:59:55.421Z cpu14:66417)WARNING: NMP: nmpDeviceAttemptFailover:640: Retry world failover device "naa.6000d310041df200000000000000000b" - issuing command 0x439d80fff3c0 2019-01-25T21:59:55.421Z cpu14:66417)WARNING: NMP: nmp_SelectPathAndIssueCommand:4633: PSP selected path "vmhba4:C0:T1:L7" in a bad state (standby) on device "naa.6000d310041df200000000000000000b". 2019-01-25T21:59:55.421Z cpu14:66417)WARNING: NMP: nmpCompleteRetryForPath:357: Retry cmd 0x12 (0x439d80fff3c0) to dev "naa.6000d310041df200000000000000000b" failed on path "vmhba4:C0:T1:L7" H:0x1 D:0x0 P:0x0 Invalid sense data: 0x0 0x0 ### vmkernel logs shows clearly that NMP is trying to access device on standby path
In the Dell EMC Storage Compatibility Matrix, the 6.5 VMWare ESXi version is tested / supported with SAS front end connectivity. SAS driver "lsi-msgpt3" Version 12 and SCOS Versions 7.2.x and 7.3.x were included in this tested and supported solution. However, upgrades to VMWare ESXi 6.5 U1, 6.5 U2, and 6.7 automatically install updated lsi-msgpt3 SAS drivers, such as Version 16. Without manual intervention of configuring a module parameter on the driver, lsi-msgpt3 versions greater than 12 do not work properly (e.g., rebooting host sees LUN capacity of 0 bytes, lose access to SAS Front End volumes upon controller failover, PSOD kernel dumps) with ESXi 6.5 and SCOS.
Storage Center systems with Front End SAS connectivity have been officially tested and supported to work with ESXi version 6.7 .f you are encountering issues with ESXi 6.5 and SCOS 7.2 / 7.3, then the best practice setting is to modify the module parameter for all versions of the lsi-msgpt3 SAS driver. It is a requirement for any version greater than 12.
Host is unable to mount the datastores after reboot
List out the module parameter values esxcli system module parameters list -m lsi_msgpt3 Modify the issue_scsi_cmd_to_bringup_drive module parameter esxcli system module parameters set -p issue_scsi_cmd_to_bringup_drive=0 -m lsi_msgpt3 Validate that the module parameter value has been modified with the list command in Step 1Reboot the ESXi host for the changed value to take effect.
https://www.dell.com/support/article/us/en/04/sln313031/sc-storage-customer-notification-driver-compatibility-with-front-end-sas-connectivity?lang=en