Following error messages noticed in Jboss.log and Powerup.log post changing ControlDaemon user password-Powerup.log:2017-05-22 13:45:44,675 DEBUG [com.powerup.configmgr.server.security.axis.handlers.AuthenticationHandler] (http-0.0.0.0-8881-1) Authenticating as user: controlDaemon2017-05-22 13:45:44,679 DEBUG [com.powerup.configmgr.server.security.login.CompositeLoginModule] (http-0.0.0.0-8881-1) Check shared credentials exist2017-05-22 13:45:44,679 DEBUG [com.powerup.configmgr.server.security.login.CompositeLoginModule] (http-0.0.0.0-8881-1) Performing authentication for user - controlDaemon2017-05-22 13:45:44,679 ERROR [com.powerup.configmgr.server.security.login.CompositeLoginModule] (http-0.0.0.0-8881-1) Incorrect password for user - controlDaemonJboss.log:2017-05-22 13:45:47,705 ERROR [org.jboss.ejb.plugins.SecurityInterceptor] (http-0.0.0.0-8881-1) Error in Security Interceptorjava.lang.SecurityException: Authentication exception, principal=controlDaemon
The password has not been synchronized in all of the device servers connected to the application server.
Steps to resolve the issue-1) Change the Controldaemon password again by using "password-change.pl" script located under $VOYENCE_HOME/tools/ on AS. Ex:[root@bngsmartsncm4 tools]# ./password-change.pla) The Password Update Utility will launch.Enter option "C" (Change single password):+========================================================+| Password Update Utility |+========================================================+| Available Commands: || [A]uto-Generate All Passwords || [C]hange Single Password || [S]ychronize from App Server || [Q]uit |+========================================================+Command: cb) In List of Users, enter option "2" for controlDaemon and the new password you want to use:+========================================================+| List of Users |+--------------------------------------------------------+| 1. system || 2. controlDaemon || 3. int_mod_user || 4. jmx-user || 5. smc-user || 6. database |+========================================================+User (1-6): 2New Password: Note: You can give any password here that is desired, and this will reset the controlDaemon user password.2) Run the command "password-change.pl -s" from $VOYENCE_HOME/tools/ across all the device servers connected to the application server. Note: If it's a combination setup, then step 2 need not be performed. 3) Restart the services using the command "service vcmaster restart". The authentication error messages should not flood Jboss.log anymore post implementation of the above.
Note: $VOYENCE_HOME is the base directory wherever NCM is installed. It can be verified by executing command "source /etc/voyence.conf" and then running "$VOYENCE_HOME" to know the directory where "smarts-ncm" is installed.