Symptoms
Cannot reconfigure HA on a cluster.Reconfiguring HA on a cluster fails.You see the error: Operation timed out Removing the ESX host from the cluster and then adding it again to the cluster does not resolve the issueYou see this error in the Task Details pane in vCenter Server: Status: Operation timed out. You may see these related events:
vSphere HA agent on <<Host's Name>> in cluster <<Cluster's Name>> in <<Datacenter's Name>> is disabled The vSphere HA availability state of the host <<Host's Name>> in cluster <<Cluster's Name>> in <<Datacenter's Name>> has changed to Uninitialized The vSphere HA availability state of the host <<Host's Name>> in cluster <<Cluster's Name>> in <<Datacenter's Name>> has changed to Initialization Error vSphere HA agent for host <<Host's Name>> has an error in <<Cluster's Name>> in <<Datacenter's Name>>: vSphere HA agent cannot be correctly installed or configured
Purpose
The purpose of this article is to resolve Error - operation time out while configuring HA.
Cause
This issue occurs if the vSphere High Availability Agent service on the ESXi host is stopped.
Resolution
To resolve this issue:
Disable HA on the cluster.Select the host and click the Configuration tab.Click Security Profile / ServicesClick Properties and check the status of vSphere High Availability.Start the service if it is stopped.Enable HA on the cluster. You should now be able to reconfigure HA.
Note: If jumbo frames are configured then make sure you are able to ping the vmkernel with a minimum of 9000 packet size. For more information see, Testing VMkernel network connectivity with the vmkping command.
Related Information
Error: "vSphere HA agent cannot be correctly installed or configured"Troubleshooting VMware High Availability (HA) issues in VMware vCenter Server 5.x and 6.0 Configuring HA after upgrading to vCenter Server 5.0 fails with the error: Cannot complete the configuration of the vSphere HA agent on the host. Misconfiguration in the host setupCannot install the vSphere HA (FDM) agent on an ESXi 5.0 host when in Lockdown Mode"Operation Timed out" error while configuring HA in vCenter Serverクラスタの HA (FDM) の再構成が次のエラーで失敗する:操作がタイムアウトしました (Operation timed out)