You experience purple diagnostic screens that contain information similar to: VMware ESX [Releasebuild-164009 X86_64] #GP Exception(13) in world 4130:helper13-0 @ 0x41803399e303 VMware ESX Server [Releasebuild-123630] #PF Exception type 14 in world 1024:console @ 0x67f0ae
Notes: If you have an "Exception 14" purple diagnostic screen that exactly matches the symptoms outlined in this article, see VMware ESX 3.5 Update 5, Patch ESX350-200911201-UG: Updates VMkernel, Service Console, hostd (1015025).If you encounter a purple diagnostic screen that does not match the symptoms above, see Interpreting an ESX/ESXi host purple diagnostic screen (1004250).If the error has not been documented within the Knowledge Base, collect diagnostic information from the ESX host and submit a support request. For more information, see Collecting diagnostic information for VMware products (1008524) and How to Submit a Support Request.
Overview Operating systems manage the physical memory on a system by employing several methods: Virtual memory or paging is designed to abstract the physical memory into virtual memory. This abstraction allows the operating system to allocate memory specific to programs and allows for other forms of memory management, including Memory Swapping, Shared Memory, and Memory Protection. Memory Swapping occurs when operating systems optimize memory by moving data that is not being used to slower mediums and vice versa. Shared Memory is a method commonly used if multiple programs need to communicate with each other. Shared memory allows multiple programs to access the same page of memory. Memory Protection prevents a malicious or malfunctioning program from accessing memory pages from other programs. When a critical application has difficulty accessing memory, it generally manifests with an error involving one of these memory management operations. Exception 13: General Protection Fault A general protection fault (Exception 13) occurs under one of these circumstances: The page being requested does not belong to the program requesting it (and is not mapped in program memory)The program does not have rights to perform a read or write operation on the page Operating systems maintain a page table that include flags to mark pages as protected. If there is a conflict between the operation and the flag, the operating system traps the illegal request. Note: Segmentation faults are very similar to general protection faults. This is a sample of a General Protection Fault generated by ESX: [VMware ESX [Releasebuild-164009 X86_64#GP Exception(13) in world 4130:helper13-0 @ 0x41803399e303frame=0x4100c0117d78 ip=0x41803399e303 cr2=0x0 cr3=0xcff94000err=0 rflags=0x10246 cr4=0x16crax=0x0 rbx=0x417ff492dbe0 rcx=0x417ff386cc80rdx=0x4100c0117f00 rbp=0x4100c0117f40 rsi=0x4100c0117e30rdi=0x410008c46220 r8=0x4100c0117e30 r9=0x4100c0117d50r10=0x3713e1b91ddd3 r11=0x41803399e1fc r12=0x4100c004fde0r13=0x410008c46220 r14=0x4100c0117e30 r15=0x417ff36146600:4096/console *1:4130/helper13- 2:4098/idle2 3:4099/idle3@BlueScreen: #GP Exception(13) in world 4130:helper13-0 @ 0x41803399e303Code starts at 0x4180336000000x4100c0117f40:[0x41803399e303]GetDriverInfo+0x106 stack: 0x410002086ba80x4100c0117f80:[0x4180336d9ef3]UplinkProcessAsyncCallsHelperCB+0x126 stack: 0x00x4100c0117ff0:[0x418033663670]helpFunc+0x4f7 stack: 0x00x4100c0117ff8:[0x0]Unknown stack: 0x0VMK uptime: 5:13:53:05.627 TSC: 968936502031893VMK checksum BAD: 0x3ee854ad7f0856e5 0x7009aad95a9042d9FSbase (0x0) GSbase (0x0) kernelGSbase (0x0) The Exception 13 General Protection Fault may be caused by either a hardware or a software issue. As the cause may vary significantly for these types of exceptions, a core-dump review may be performed by VMware. This process is usually not possible to perform without access to protected source code and analysis tools or processes. Collect diagnostic information from the VMware ESX host and submit a support request. For more information, see Collecting diagnostic information for VMware products (1008524) and How to Submit a Support Request. You can also contact your hardware vendor if you or VMware Technical Support are able to determine that a particular driver module or device has caused the exception. Exception 14: Page Fault A page fault (Exception 14) occurs when the page being requested has not been successfully loaded into memory. There are both healthy and unhealthy page faults: A healthy page fault results in the page being loaded from swapped memory to physical memory. The program is then allowed to proceed after the data has been properly loaded into physical memory.An unhealthy page fault occurs when the page is not loaded in memory, and the operating system is unable to load the page from swapped to physical memory. This is a sample of a Page Fault generated by ESX: [VMware ESX Server [Releasebuild-123630]Exception type 14 in world 1024:console @ 0x67f0aeframe=0x1402824 ip=0x67f0ae cr2=0x405f6000 cr3=0x13401000 cr4=0x6f0es=0x4028 ds=0x40404028 fs=0xffff0000 gs=0x0eax=0x409f6000 ebx=0x1000 ecx=0x400 edx=0x409f6000ebp=0x14028b4 esi=0x407c8000 edi=0x409f6000 err=11 eflags=0x10206*0:1024/console 1:1092/mks:ubunt 2:1089/vmware-vm 3:1027/idle34:1028/idle4 5:1029/idle5 6:1030/idle6 7:1091/vmware-vm8:1032/idle8 9:1033/idle9 10:1034/idle10 11:1093/vcpu-0:ub12:1036/idle12 13:1037/idle13 14:1038/idle14 15:1039/idle15@BlueScreen: Exception type 14 in world 1024:console @ 0x67f0ae0x14028b4:[0x67f0ae]genericCopy+0x155 stack: 0xc0bbc60, 0x40081800, 0x00x14028dc:[0x67f3d6]vmk_SgCopy+0x41 stack: 0xc0bbc60, 0x40081800, 0x00x140292c:[0x7cef13]SCSICompleteFragment+0x1ae stack: 0xc005d00, 0x0, 0xc31000x14029c4:[0x7d081c]SCSICompletePathCommand+0x453 stack: 0xc005d00, 0x125, 0x148a4f80x1402a60:[0x7cafff]SCSICompleteAdapterCommand+0x3da stack: 0xc005d00, 0x2, 0x1402de00x1402ac0:[0x88343f]vmk_scsi_dump_active+0x20e stack: 0x0, 0x10a, 0x6a525f00x1402b30:[0x61811e]BHCallHandlersInt+0xf5 stack: 0x2ad0, 0x0, 0x1402b880x1402b88:[0x618614]BH_Check+0x2bb stack: 0x1, 0x1402bac, 0x1752d490x1402bac:[0x61fb8e]IDT_HandleInterrupt+0x85 stack: 0x1402bf8, 0x0, 0xb6380000x1402bc0:[0x61fcb5]IDT_IntrHandler+0x4c stack: 0x1402bf8, 0x4028, 0x14540280x1402c70:[0x692c6c]CommonIntr+0xb stack: 0x1489500, 0x0, 0x1402de00x1402e1c:[0x7615e4]CpuSchedDispatch+0x487 stack: 0x2390a60, 0x1489500, 0x00x1402e88:[0x763eaa]CpuSchedDoWaitDirectedYield+0x351 stack: 0x0, 0x1f55e60, 0x00x1402ea4:[0x763fda]CpuSched_WaitIRQ+0x31 stack: 0xfedcba90, 0x6, 0x1f55e600x1402ec4:[0x69197f]VMNIXVMKSyscall_Idle+0xe2 stack: 0x1402f6c, 0x6915cf, 0x00x1402ecc:[0x68669c]VMNIXVMKSyscallUnpackIdle+0x7 stack: 0x0, 0x0, 0x00x1402f6c:[0x6915cf]HostSyscall+0xf6 stack: 0x1402fbc, 0xc03d9f98, 0x1c0x1402fe8:[0x6909e3]HostVMKEntry+0xce stack: 0x0, 0x0, 0x0VMK uptime: 0:01:58:34.004 TSC: 15137542595232Starting coredump to disk Starting coredump to disk Dumping using slot 1 of 1... using slot 1 of 1... log The Exception 14 Page Fault may be caused by either a hardware or a software issue. As the cause may vary significantly for these types of exceptions, a core-dump review may be performed by VMware. This process is usually not possible to perform without access to protected source code and analysis tools or processes. Collect diagnostic information from the VMware ESX host and submit a support request. For more information, see Collecting diagnostic information for VMware products (1008524) and How to Submit a Support Request. You can also contact your hardware vendor if you or VMware Technical Support are able to determine a particular driver module or device has caused the exception. To find our more about page-fault exceptions, see the Formats and Encodings of SSE2 Floating-Point Instructions table in the Intel 64 and IA-32 Architectures Software Developer’s Manual. Note: See VMware ESXi 5.x host experiences a purple diagnostic screen mentioning E1000PollRxRing and E1000DevRx (2059053) for more information about a common cause and resolution for a page fault exception in vSphere ESXi.
Interpreting an ESX/ESXi host purple diagnostic screenCollecting diagnostic information for VMware products VMware ESX 3.5 Update 5, Patch ESX350-200911201-UG: Updates VMkernel, Service Console, hostdComo compreender os eventos da tela de diagnóstico roxa Exception 13 e Exception 14 no ESX 3.x/4.x e ESXi 3.x/4.x/5.xComprensión de los mensajes Excepción 13 y Excepción 14 de las pantallas de diagnóstico de color púrpura en ESX 3.x/4.x y ESXi 3.x/4.x/5.xESXi 5.x with E1000e adapter fails with purple diagnostic screen了解 ESX 3.x/4.x 和 ESXi 3.x/4.x/5.x/6.x 中的异常 13 和异常 14 紫色诊断屏幕(紫屏)事件ESX 3.x/4.x および ESXi 3.x/4.x/5.x における、Exception 13 および Exception 14 の紫色の診断画面イベントについて