vMotion fails at 10% You see these errors in vCenter Server: A general system error occurred: Migration failed while copying data, Broken PipeMigration failed while copying data. Connection reset by peer A general system error occured: Failed to start migration pre-copy Error 0xbad010d. The Esx host failed connect over the VMotion network. You see this error in the /var/log/messages (ESXi host) or /var/log/vmkernel (ESX host) log file:The ESX hosts failed to connect over the VMotion network Module Migrate power on failed vmkping testing on the VMkernel network used for vMotion is successfulNote: For more information, see Testing VMkernel network connectivity with the vmkping command (1003728). Disabling and re-enabling vMotion on the VMkernel port used for vMotion in vCenter does not resolve this issue In the /var/log/vmkernel log file of the source ESX host, you see this warning:WARNING: MigrateNet: 210: 4225417790: 2-0x3fa0c8d0:Received only 0 of 68 bytes: Migration protocol error In the /var/log/vmkernel log file of the destination ESX host, you see these messages: WARNING: Migrate: 1153: 4225417790: Failed: I/O error (0xbad000a) @0x8d7c03 ESX hosts failed to connect over the VMotion network (0xbad010d) @0x0 Feb 22 14:14:04 esx1 vmkernel: 402:01:22:35.133 cpu6:1939)Migrate: vm 1940: 7338: Setting migration info ts = 1298397818667246, src ip = <192.168.103.48> dest ip = <192.168.103.7> Dest wid = 5272 using SHARED swapFeb 22 14:14:04 esx1 vmkernel: 402:01:22:35.134 cpu6:1939)World: vm 3330: 900: Starting world migSendHelper-1940 with flags 1Feb 22 14:14:04 esx1 vmkernel: 402:01:22:35.134 cpu6:1939)World: vm 4355: 900: Starting world migRecvHelper-1940 with flags 1Feb 22 14:14:04 esx1 vmkernel: 402:01:22:35.136 cpu4:3330)WARNING: MigrateNet: 309: 1298397818667246: 5-0x801f640:Sent only 4020 of 4096 bytes of message data: Broken pipeFeb 22 14:14:04 esx1 vmkernel: 402:01:22:35.136 cpu4:3330)WARNING: Migrate: 6776: 1298397818667246: Couldn't send data for 8: Broken pipeFeb 22 14:14:04 esx1 vmkernel: 402:01:22:35.136 cpu4:3330)WARNING: Migrate: 1243: 1298397818667246: Failed: Broken pipe (0xbad0052) @0x9efd5f The /var/log/vmware/hostd.log (ESX) and /var/log/messages (ESXi) contains an entry similar to:Apr 8 11:24:44 Hostd: [2011-04-08 11:24:44.929 37903B90 verbose 'vm:/vmfs/volumes/4c220e6f-01b124b3-f25d-e41f132dae86/twidmann_test/twidmann_test.vmx'] VMotionLastStatusCb: Failed with error 536871181: Failed to start migration pre-copy. Error 0xbaApr 8 11:24:44 d010d. The ESX hosts failed to connect over the VMotion network.Apr 8 11:24:44 Hostd: [2011-04-08 11:24:44.929 37903B90 verbose 'vm:/vmfs/volumes/4c220e6f-01b124b3-f25d-e41f132dae86/twidmann_test/twidmann_test.vmx'] VMotionResolveCheck: Operation in progressApr 8 11:24:44 Hostd: [2011-04-08 11:24:44.929 37903B90 verbose 'vm:/vmfs/volumes/4c220e6f-01b124b3-f25d-e41f132dae86/twidmann_test/twidmann_test.vmx'] VMotionStatusCb: CompletedApr 8 11:24:44 Hostd: [2011-04-08 11:24:44.929 37903B90 verbose 'vm:/vmfs/volumes/4c220e6f-01b124b3-f25d-e41f132dae86/twidmann_test/twidmann_test.vmx'] VMotionResolveCheck: Firing ResolveCbApr 8 11:24:44 Hostd: [2011-04-08 11:24:44.929 37903B90 info 'VMotionSrc (1302261872027749)'] ResolveCb: VMX reports needsUnregister = false for migrateType MIGRATE_TYPE_VMOTIONApr 8 11:24:44 Hostd: [2011-04-08 11:24:44.929 37903B90 info 'VMotionSrc (1302261872027749)'] ResolveCb: Failed with fault: (vmodl.fault.SystemError) {Apr 8 11:24:44 Hostd: dynamicType = <unset>,Apr 8 11:24:44 Hostd: faultCause = (vmodl.MethodFault) null,Apr 8 11:24:44 Hostd: reason = "Failed to start migration pre-copy. Error 0xbad010d. The ESX hosts failed to connect over the VMotion network.Apr 8 11:24:44 Hostd: ",Apr 8 11:24:44 Hostd: msg = "",Apr 8 11:24:44 Hostd: }Apr 8 11:24:44 Hostd: [2011-04-08 11:24:44.929 37903B90 verbose 'VMotionSrc (1302261872027749)'] Migration changed state from MIGRATING to DONEApr 8 11:24:44 Hostd: [2011-04-08 11:24:44.929 37903B90 verbose 'VMotionSrc (1302261872027749)'] Finish calledApr 8 11:24:44 Hostd: [2011-04-08 11:24:44.929 366A9B90 info 'vm:/vmfs/volumes/4c220e6f-01b124b3-f25d-e41f132dae86/twidmann_test/twidmann_test.vmx'] Disconnect check in progress.
This is a known issue affecting ESXi/ESX 4.0 This issue is resolved in ESXi/ESX 4.0 Update 2 and is being investigated by VMware for the other affected versions. To download ESXi/ESX 4.0 Update 2, see Download VMware vSphere. If you cannot upgrade, or you experience these symptoms in a newer version, you can workaround this issue by resetting the Migrate.Enabled setting on both the source and destination hosts. Note: This issue may re-occur even after applying the workaround. To reset the Migrate.Enabled setting: Connect vSphere or VMware Infrastructure Client to your vCenter Server. Click on the ESX host. Click the Configuration tab. Click Advanced Settings under Software. Select Migrate and change Migrate.Enabled to 0. Click OK and close. Click on Advanced Settings. Select Migrate and change Migrate.Enabled to 1. Click OK and then Close. Note: If you see the invalid parametererror after resetting Migrate.Enabled to 1, see Performing a vMotion or adding a network card to a virtual machine fails with the error: Necessary module isn't loaded. (2013128) If these steps do not resolve the issue, try increasing the timeout for migration network operations after Step 4 and then continue with the remaining steps. Also, ensure to repeat these steps on the destination host. To increase the timeout for migration network operations: Click the Configuration tab. Click Advanced Settings under Software > Migrate. Change Migrate.NetTimeout to 60 seconds. The default is 20 seconds. Click OK and then Close. Note: This issue may also occur due to a duplicate IP address on your network. Ensure that the IP addresses for your vCenter Servers and ESX/ESXi hosts are unique.
For more information, see Diagnosing a vMotion failure at 10% or higher in vCenter Server (1003734). Testing VMkernel network connectivity with the vmkping commandUnderstanding and troubleshooting vMotionPerforming a vMotion or adding a network card to a virtual machine fails with the error: Necessary module isn't loadedFalha de vMotion a 10% com o erro: Ocorreu um erro geral no sistema: falha na migração ao copiar dados, redirecionamento desfeitovMotion falla al 10 % con el error: A general system error occurred: Migration failed while copying data, Broken PipevMotion 到 10% 时失败并显示错误:“出现了常规系统错误: 复制数据时迁移失败,管道已损坏”「一般的なシステム エラーが発生しました:データのコピー中に移行が失敗しました。破損したパイプ」というエラーが発生して vMotion が 10% の時点で失敗する