Challenge
A Restore to Amazon EC2 fails with the error:
Failed to validate machine <name>: Cannot find a suitable image for restored machine.
Cause
The default list of Windows Images that Veeam Backup & Replication attempts to reference contains images that were recently removed from AWS.
Solution
Note: This issue will be resolved in the next release of Veeam Backup & Replication.
To resolve this issue in Veeam Backup & Replication versions 11/11a/12, create the following registry value on the Veeam Backup Server:
Key Location: HKLM\SOFTWARE\Veeam\Veeam Backup and ReplicationValue Name: AmazonDefaultWindowsImageValue Type: Multi-String Value (REG_MULTI_SZ)Value Data: <see code block below>
Tip: Hover over the code block and click the copy button in the top-right corner.
More Information
Example of correct registry value configuration: