Operational Defect Database

BugZero found this defect 3523 days ago.

Veeam | kb1971

Issue with Hyper-V Reports in MP builds 7.0.0.1911 and 7.0.0.1913

Last update date:

8/13/2020

Affected products:

No affected products provided.

Affected releases:

Fixed releases:

No fixed releases provided.

Description:

Challenge

The following Hyper-V reports show no performance data: Performance Forecast for Hyper-V Clusters Performance Forecast for Hyper-V Storage Host Failure Modelling What-If VM Deployment Planning (model existing VMs What-If VM Deployment Planning (manual resource entry) Virtual Machines. Right-sizing — VMs Oversized for Memory and CPU Virtual Machines. Right-sizing — VMs Undersized for Memory and CPU The ‘Virtual Machines. Idle VMs’ report shows no data for the % Memory Pressure metric.The following Hyper-V report fails with error “An item with the same key has already been added”. Configuration Tracking and Alert Correlation

Cause

This is a known issue in the following builds of these Veeam MPs –  MP Name Version Veeam Hyper-V Analysis Reports 7.0.0.1911 Veeam Hyper-V Views 7.0.0.1913 Veeam Hyper-V Monitoring 7.0.0.1913

Solution

The issue is resolved in the following Veeam MP builds –   MP Name Version Veeam Hyper-V Analysis Reports 7.0.0.1913 Veeam Hyper-V Views 7.0.0.1914 Veeam Hyper-V Monitoring 7.0.0.1914

More Information

The updated MPs are available in the latest MP 7.0 R2 download ISO or as a patch (zip file containing all 7.0 R2 MPs) from the patch download page.