Issue
Description of problem:
Using Image Builder I've created an edge installer. When I try to create a custom data partion (/data) I get the error during the installation progress "The following error occurred while installing the payload. This a fatal error and installation will be aborted. The command 'mount --bind /mnt/sysimage/data /mnt/sysroot/data' exited with the code 32.
I've seen that if I create the data directory in a separate console under /mnt/sysimage and then making again mount --rbind /mnt/sysimage /mnt/sysroot the directory is properly created.
Version-Release number of selected component (if applicable):
RHEL 9
anaconda 34.25.0.29
composer-cli v35.5
API server status:
Database version:
0
Database supported: true
Schema version:
0
API version:
1
Backend:
osbuild-composer
Build:
NEVRA:osbuild-composer-46.3-1.el9_0.x86_64
How reproducible: everytime
Steps to Reproduce:
1. Select Installation Destination
2. Select Storage Configuration as Custom
3. Add a new mount point with Mount Point "/data" and Desiderd Capacity: 2 GiB
4. Accept changes
5. Begin installation
Actual results:
Installation reports "The following error occurred while installing the payload. This a fatal error and installation will be aborted. The command 'mount --bind /mnt/sysimage/data /mnt/sysroot/data' exited with the code 32."
Expected results:
Installation complete with success.
Additional info: