Palo Alto Networks | PAN-110511

Fixed an issue where a passive Panorama appliance reported that device groups were out of sync despite a successful HA sync from the active Panorama appliance. This issue occurred when the address objects defined in the device group were in use under the corresponding template.

Last update date:

5/23/2024

Affected products:

Pan OS

Affected releases:

No affected releases provided.

Fixed releases:

9.1.6

Description:

The earliest recollection of this bug is traced back to PAN-OS 9.1.6 - May 23, 2024. This bug is fixed in PAN-OS versions 9.1.6. Fixed an issue where a passive Panorama appliance reported that device groups were out of sync despite a successful HA sync from the active Panorama appliance. This issue occurred when the address objects defined in the device group were in use under the corresponding template. For more information: https://docs.paloaltonetworks.com/pan-os/9-1/pan-os-release-notes/pan-os-9-1-addressed-issues/pan-os-9-1-6-addressed-issues