Operational Defect Database

BugZero found this defect 387 days ago.

| D9B30C5F

Meraki native switches move LACP ports to an active forwarding state if configured. This can cause loops when connecting to an MS390 or other Catalyst switch unless the bundles are configured on the Catalyst side first. All Meraki native ports are configured in passive LACP mode so that loops do not occur between Meraki native switches (always present)

Last update date:

7/6/2023

Affected products:

Meraki CS Catalyst Switches

Affected releases:

16.8

16.3

16.5

16.2

16.4

17.1.1

17.1.2.1

16.6

16.7

Fixed releases:

No fixed releases provided.

Description:

Meraki native switches move LACP ports to an active forwarding state if configured. This can cause loops when connecting to an MS390 or other Catalyst switch unless the bundles are configured on the Catalyst side first. All Meraki native ports are configured in passive LACP mode so that loops do not occur between Meraki native switches (always present)