Symptoms
During the platform migration from a physical BIG-IP system to a BIG-IP vCMP guest/F5OS Tenant, the load fails with one of the following messages:
01070687:3: Link Aggregation Control Protocol (LACP) is not supported on this platform. Unexpected Error: Loading configuration process failed.
01070338:3: Cannot create trunk [name of trunk], maximum limit reached Unexpected Error: Loading configuration process failed.
Impact
The platform migration fails and the configuration does not load.
Conditions
-- The source device is a physical BIG-IP device with one or more trunks with or without LACP in its configuration.
-- The destination device is a vCMP guest/F5OS Tenant.
Workaround
You can use one of the following workarounds:
-- Remove all trunks from the source configuration prior to generation of the UCS.
-- Before loading the UCS archive onto the target BIG-IP, edit the archive and remove the trunk configuration from ./config/bigip_base.conf, and then repack the UCS.
-- After the UCS load fails, edit the configuration manually on the destination to remove trunk references, and then reload the configuration.
-- K50152613