Symptoms
When virtual server has rewrite-uri-translation rewrite profile with Client value of / and an Access Policy is also on that virtual server then the connection will reset, reset cause will be "Access encountered an error (Out of memory..."
Impact
- Clients fail to connect to virtual server solution
- FSE's customer POC is failing
Conditions
Connection reset with out of memory.
- Virtual Server
- Access Policy
- rewrite-uri-translation rewrite profile
- URI Rules -> Client value is /
Workaround
Do not use / as a Client value within a URI Rule within a rewrite-uri-translation rewrite profile
Do not specify an Access Policy and a rewrite-uri-translation rewrite profile that has a / as Client value within a URI Rule