Log messages similar to the following may be observed in /var/log/ltm: bigip1 err mcpd[4783]: 01070712:3: Caught configuration exception (0), Invalid monitor rule instance identifier: 29. This may also result in a few unresponsive monitors in checking state. If this occurs on a VIPRION system or a multi-slot tenant on a VELOS system, one or more secondary blades may reboot repeatedly while logging messages similar to the following: err mcpd[####]: 01020036:3: The requested monitor instance (/Common/?????? ##.##.##.## ### ?????????) was not found. err mcpd[####]: 01070734:3: Configuration error: Configuration from primary failed validation: 01020036:3: The requested monitor instance (/Common/?????? ##.##.##.## ### ?????????) was not found.... failed validation with error 16908342.
-- A few monitor statuses may not be correctly reported. -- A few monitors may be unresponsive in checking state. -- On VIPRION or VELOS systems, one or more secondary blades may be unresponsive in a reboot loop.
The initial "requested monitor instance ... was not found" message may occur when: -- FQDN nodes exist on the configuration. -- A full config sync occurs. -- Device contains a fix for Bug ID 1017513. -- May happen regardless of bigd or in-tmm monitoring. In addition, the message "Configuration error: Configuration from primary failed validation" and secondary blade/slot reboot loop may occur on VIPRION or VELOS systems.
Force the MCPD process to reload the BIG-IP configuration. For more information refer K13030.
The monitors are responsive, no errors are recorded.
F5 Integration
Learn more about where this data comes from
Bug Scrub Advisor
Streamline upgrades with automated vendor bug scrubs
BugZero Enterprise
Wish you caught this bug sooner? Get proactive today.