OPERATIONAL DEFECT DATABASE
...

...
Bug ID 1055077: Modifying the datacenter does not check GTM server configuration for prober-pool. ... If GTM is in a bad configuration state, the reload can fail with an error similar to this: 01071b63:3: The prober fallback value for server /Common/server1 cannot be the same as the inherited prober preference value. ... Unexpected Error: Validating configuration process failed. ... or 01071b62:3: The prober preference value for server /Common/server2 cannot be the same as the inherited prober fallback value. ... Two prober-pool configurations for a GSLB server is a prohibited state. ... Once this state is reached, any action that tries to validate the configuration (like a configuration load) will fail. ... This can cause the BIG-IP to fail to load configuration or cause a UCS restore to fail. ... Conditions ... 1. GSLB server has a prober-pool and inherits the datacenter selected for prober preference or prober fallback (it does not matter which prober configuration has which value).
Click on a version to see all relevant bugs
F5 Integration
Learn more about where this data comes from
Bug Scrub Advisor
Streamline upgrades with automated vendor bug scrubs
BugZero Enterprise
Wish you caught this bug sooner? Get proactive today.