iDRAC Firmware update and ISM failed with following error:================================================idpa-acm:/data01/upgrade # /usr/local/dpatools/bin/workarounds.shWork around PTAgent issue............{"Response":"Workaround PTAgent issue: Succeeded"}Updating iDRAC firmware......Failed to execute DPA CLI command: I/O error on POST request for "https://192.168.100.101:8086/api/PT/v1/host/SMF/payloads": Connect to 192.168.100.101:8086 [/192.168.100.101] failed: Connection refused (Connection refused); nested exception is org.apache.http.conn.HttpHostConnectException: Connect to 192.168.100.101:8086 [/192.168.100.101] failed: Connection refused (Connection refused)usage: Data Protection Appliance Tools -fwupdate Copy firmware payload to host for update -skipReboot Skip system reboot after fwupdate[WARN] [02/25/2020 21:51:32.063] [DPACLI-System-shutdown-hook-1] [CoordinatedShutdown(akka://DPACLI-System)] CoordinatedShutdown from JVM shutdown failed: Futures timed out after [10000 milliseconds]/usr/local/dpatools/logs/dpacli.log also shows the same error:==============================================2020-02-26T03:02:22.223Z ERROR [] [DPACLI-System-akka.actor.default-dispatcher-4] [][][][][] com.emc.dpa.common.akka.DPAHostAdapter - An exception is thrown when executing dpacli command. Check the dpacli logs for additional informationorg.springframework.web.client.ResourceAccessException: I/O error on POST request for "https://192.168.100.101:8086/api/PT/v1/host/SMF/payloads": Connect to 192.168.100.101:8086 [/192.168.100.101] failed: Connection refused (Connection refused); nested exception is org.apache.http.conn.HttpHostConnectException: Connect to 192.168.100.101:8086 [/192.168.100.101] failed: Connection refused (Connection refused) at org.springframework.web.client.RestTemplate.doExecute(RestTemplate.java:666) at org.springframework.web.client.RestTemplate.execute(RestTemplate.java:613) at org.springframework.web.client.RestTemplate.exchange(RestTemplate.java:531) at com.emc.dpa.ptclient.PowerToolsRestClient.executeInternal(PowerToolsRestClient.java:232) at com.emc.dpa.ptclient.PowerToolsRestClient.executeRequest2(PowerToolsRestClient.java:455) at com.emc.dpa.ptresources.DPAResourceBuilder.updateHostFW(DPAResourceBuilder.java:670) at com.emc.dpa.ptresources.DPAResourceBuilder.updateFW(DPAResourceBuilder.java:537) at com.emc.dpa.ptresources.PTCLIService.updateFW(PTCLIService.java:73) at com.emc.dpa.common.akka.DPAHostAdapter.receiveDPAOpMessage(DPAHostAdapter.java:276) at akka.japi.pf.UnitCaseStatement.apply(CaseStatements.scala:26) at akka.japi.pf.UnitCaseStatement.apply(CaseStatements.scala:21) at scala.PartialFunction.applyOrElse(PartialFunction.scala:123) at scala.PartialFunction.applyOrElse$(PartialFunction.scala:122) at akka.japi.pf.UnitCaseStatement.applyOrElse(CaseStatements.scala:21) at scala.PartialFunction$OrElse.applyOrElse(PartialFunction.scala:171) at akka.actor.Actor.aroundReceive(Actor.scala:517) at akka.actor.Actor.aroundReceive$(Actor.scala:515) at akka.actor.AbstractActor.aroundReceive(AbstractActor.scala:180) at akka.actor.ActorCell.receiveMessage(ActorCell.scala:588) at akka.actor.ActorCell.invoke(ActorCell.scala:557) at akka.dispatch.Mailbox.processMailbox(Mailbox.scala:258) at akka.dispatch.Mailbox.run(Mailbox.scala:225) at akka.dispatch.Mailbox.exec(Mailbox.scala:235) at akka.dispatch.forkjoin.ForkJoinTask.doExec(ForkJoinTask.java:260) at akka.dispatch.forkjoin.ForkJoinPool$WorkQueue.runTask(ForkJoinPool.java:1339) at akka.dispatch.forkjoin.ForkJoinPool.runWorker(ForkJoinPool.java:1979) at akka.dispatch.forkjoin.ForkJoinWorkerThread.run(ForkJoinWorkerThread.java:107)Caused by: org.apache.http.conn.HttpHostConnectException: Connect to 192.168.100.101:8086 [/192.168.100.101] failed: Connection refused (Connection refused) at org.apache.http.impl.conn.DefaultHttpClientConnectionOperator.connect(DefaultHttpClientConnectionOperator.java:159) at org.apache.http.impl.conn.PoolingHttpClientConnectionManager.connect(PoolingHttpClientConnectionManager.java:373) at org.apache.http.impl.execchain.MainClientExec.establishRoute(MainClientExec.java:381) at org.apache.http.impl.execchain.MainClientExec.execute(MainClientExec.java:237) at org.apache.http.impl.execchain.ProtocolExec.execute(ProtocolExec.java:185) at org.apache.http.impl.execchain.RetryExec.execute(RetryExec.java:89) at org.apache.http.impl.execchain.RedirectExec.execute(RedirectExec.java:111) at org.apache.http.impl.client.InternalHttpClient.doExecute(InternalHttpClient.java:185) at org.apache.http.impl.client.CloseableHttpClient.execute(CloseableHttpClient.java:83) at org.apache.http.impl.client.CloseableHttpClient.execute(CloseableHttpClient.java:56) at org.springframework.http.client.HttpComponentsStreamingClientHttpRequest.executeInternal(HttpComponentsStreamingClientHttpRequest.java:98) at org.springframework.http.client.AbstractClientHttpRequest.execute(AbstractClientHttpRequest.java:53) at org.springframework.web.client.RestTemplate.doExecute(RestTemplate.java:652) ... 26 common frames omittedCaused by: java.net.ConnectException: Connection refused (Connection refused) at java.net.PlainSocketImpl.socketConnect(Native Method) at java.net.AbstractPlainSocketImpl.doConnect(AbstractPlainSocketImpl.java:350) at java.net.AbstractPlainSocketImpl.connectToAddress(AbstractPlainSocketImpl.java:206) at java.net.AbstractPlainSocketImpl.connect(AbstractPlainSocketImpl.java:188) at java.net.SocksSocketImpl.connect(SocksSocketImpl.java:392) at java.net.Socket.connect(Socket.java:606) at org.apache.http.conn.ssl.SSLConnectionSocketFactory.connectSocket(SSLConnectionSocketFactory.java:339) at org.apache.http.impl.conn.DefaultHttpClientConnectionOperator.connect(DefaultHttpClientConnectionOperator.java:142) ... 38 common frames omitted
The current dpatools with version 2.0.0.20 is outdated
Download and install the latest dpatools from:https://inside.dell.com/docs/DOC-425832Then rerun the iDRAC firmware update command again. it will complete succesfully. Here is am example:/usr/local/dpatools/bin/workarounds.shWork around PTAgent issue............{"Response":"Workaround PTAgent issue: Succeeded"}Updating iDRAC firmware......Host x.x.x.x: 100%No reboot issued after update.Upgrading iSM to v3.4.1......Updating iSM............