Symptoms
copy running-config startup-config fabric fails as follows : MDS# copy running-config startup-config fabricThis will save the running configuration on all switches in the fabric.Do you want to continue? (y/n) [n] y[########################################] 100%Failed status for fabric wide configuration copy:-----------------------------------------------------------------------Switch WWN IP Address Status-----------------------------------------------------------------------20:xx:xx:xx:xx:xx:xx:xx 10.x.x.x request was aborted20:xx:xx:xx:xx:xx:xx:xx (local) 10.x.x.x request was abortedConfiguration update aborted: request was aborted
Cause
Further review of MDS show tech-support which reported the error:`show system internal sysmgr startup-config state`vdc = 1Opening file /mnt/pss/srv_failed_store_start_cfg: The following services failed to store their startup-config the previous time: fscm in vdc 1 failed with syserr: at least one switch response failed (0x40C0000E)Status for fabric/network wide configuration copy:-----------------------------------------------------------------------Switch WWN IP Address Status-----------------------------------------------------------------------20:xx:xx:xx:xx:xx:xx:xx 10.x.x.x request was aborted20:xx:xx:xx:xx:xx:xx:xx 10.x.x.x success20:xx:xx:xx:xx:xx:xx:xx 10.x.x.x success20:xx:xx:xx:xx:xx:xx:xx (local) 10.x.x.x request was aborted20:xx:xx:xx:xx:xx:xx:xx 10.x.x.x success20:xx:xx:xx:xx:xx:xx:xx 10.x.x.x success
Resolution
Fix:Upon review of Switches that failed to perform a 'copy run start' the following services showed as failed thus impeding the 'copy running-config startup-config fabric' as follows:Switch 1:SYSMGR-3-CFGWRITE_SRVFAILED: Service "fscm" failed to store its configuration (error-id 0x40C0000E).Switch 2:SYSMGR-3-CFGWRITE_SRVFAILED: Service "snmpd" failed to store its configuration (error-id 0x00000006)During a maintenance, perform a supervisor switch over on the above switches to clear the condition.command syntax:-system switchover