OPERATIONAL DEFECT DATABASE
...

...
An error is reported when attempting to change Remote Management Console (RMC) settings on an Avamar Gen4T node: ipmitool lan set 4 defgw ipaddr 10.0.0.1 Setting LAN Default Gateway IP to 10.0.0.1 LAN Parameter Data does not match! Write may have failed.
The RMC port is not enabled on the Avamar Gen4T node. This can be confirmed by running the following command as root: Caution: Ensure that the syntax of the command is input exactly as shown below: ipmitool raw 0x30 0xf9 00 00 00 All zeros indicate that the RMC port is not enabled.
Follow Avamar: How to configure Remote Management Console on Gen4T nodes to enable and configure the RMC ports on Avamar Gen4T nodes.