Symptoms
Impact:D-port test failing.Environment:DELL EMC Hardware: Connectrix DS-6505BDELL EMC Hardware: Connectrix DS-6510BDELL EMC Hardware: Connectrix DS-6520BDELL EMC Hardware: Connectrix ED-8510-4BDELL EMC Hardware: Connectrix ED-8510-8BLong wave SFP start with serial number HDA3xxxxIssue:When attempting to run D Port loopback tests on certain 16gig long wave optics, the optic will fail the loopback testAn HDA3xxxx transceiver fails during external loopback with Protocol error . We also see that pcs errors clocked during the test for these ports. Example:Switchname:FID1:admin> trunkshow 1: 0-> 0 10:00:c4:f5:7c:db:70:80 11 deskew 15 MASTER 4-> 4 10:00:c4:f5:7c:db:70:80 11 deskew 16 2: 24-> 24 10:00:c4:f5:7c:db:70:80 11 deskew 15 MASTER 28-> 28 10:00:c4:f5:7c:db:70:80 11 deskew 15 Port 0: id (lw) Vendor: BROCADE Serial No: HDA21615000K242 Port 4: id (lw) Vendor: BROCADE Serial No: HDA21615000JF82 Port 24: id (lw) Vendor: BROCADE Serial No: HDA3171840000N1 Port 28: id (lw) Vendor: BROCADE Serial No: HDA317204000K01 Switchname:FID1:admin> portdporttest --show all Port State SFP Capabilities Test Result ============================================= 0 ONLINE E,O PASSED 4 ONLINE E,O PASSED 24 ONLINE E,O FAILED 28 ONLINE E,O FAILED Switchname:FID1:admin> portdporttest --show 24 Status:FAILED (Protocol error) ================================================================================ Test Start timeResultEST(HH:MM:SS)Comments ================================================================================ Electrical loopback--------FAILED ------------------ Optical loopback --------NOT STARTED------------------ Link traffic test --------NOT STARTED------------------ ================================================================================ portstatsshow 24:==================stat_wtx 353 4-byte words transmittedstat_wrx 331 4-byte words receivedstat_ftx 16 Frames transmittedstat_frx 14 Frames received er_pcs_blk 46 PCS block errors
Cause
Incorrect settings are set on HDA3xxxx optics when configured for external wrap tests. These will cause the optic to fail the test. Normal data traffic operations correctly configure the optic settings and the optic runs without issue. This specific optic (S/N starting with HDA3XXX) does not support the D port loopback test.
Resolution
Fix: Upgrade to one of the version the issue is fixed in.Fabric OS versions v8.0.2e, 8.1.2b, 8.2.0a and greater will not allow D Port electrical loopback tests to run on any ports that have Long Wave HDA3xxxx optics installed.Other D Port tests will be run on these ports under the referenced versions of FOS. The external loopback tests will be skipped. Important: If you do run D Port external wrap test on one or a few of these optics and you see the above failures occur, you will need to run the below commands to reset the optic(s) before putting it into production. portdisable portcfgdport --disable portenable Workaround: Do not run the D port loopback test