When setting up the Replication environment, first configure the appropriate Replication Interfaces [Data Protection > Replication > Interfaces] on both the Local and Remote Dell EMC Unity systems before creating the Replication Connection from the Local system.Create remote system Failed(3/23/2016, 11:56:51 AM)Although the remote system is registered, the connectivity validation has failed. Check for any network connectivity issues, and also ensure that the time skew between the systems is less than 10 minutes. Once fixed, run the verify operation on the remote system to resolve this issue. View alerts related to the remote system connections for more information. (Error Code:0x6500128)Details:Register remote system on local system CompletedRegister local system on remote system CompletedRefresh remote system connections on local system FailedRefresh local system connections on remote system Not Started Jobs: Failed: Although the remote system is registered, the connectivity validation has failed. Check for any network connectivity issues, and also ensure that the time skew between the systems is less than 10 minutes. Once fixed, run the verify operation on the remote system to resolve this issue. View alerts related to the remote system connections for more information. (Error Code:0x6500128)Rollback Result: Task was rolled back and marked as failed. This is because some tasks failed or SP rebooted during task execution. (Error Code:0x100a) Alerts: Error 14:6077cThe remote system connection failed to validate the replication interface connectivity between the two systems.One or more replication interface pairs are experiencing network connectivity issues between the local and remote systems.
You must create the correct Replication Interfaces before creating the Replication Connection between a Local and Remote system.
Remove the faulted Replication Connection. Note: Do not bypass the step to remove the Replication Connection. If you do, and create the Replication Interfaces, the Replication Session creation will fail. You must remove the faulted Connection and then follow the correct order shown below. Create the appropriate Replication Interfaces on the Local and Remote systems.Create the Replication Connection.Create Replication sessions on the appropriate NAS Server or Block LUN/Consistency Group resource.
Click on a version to see all relevant bugs
Dell Integration
Learn more about where this data comes from
Bug Scrub Advisor
Streamline upgrades with automated vendor bug scrubs
BugZero Enterprise
Wish you caught this bug sooner? Get proactive today.