Symptoms
When using the NetWorker Web User Interface (NWUI) to add a Data Domain to the NetWorker server, the Required (*) asterisk is omitted from the creation page but does appear when editing an already added Data Domain.The HOSTS is required when adding a Data Domain.In the Data Domain logs, the error is seen:
WARNING: Failed to verify the password for user ddboost. Error is 7:Authentication failure.
Cause
NWUI page does not display the (*) asterisk. Because of this the user omits adding the backup server hostname to the field. They receive an error as shown below.
The * is missing next to
Resolution
When creating the Data Domain, you must add:
The Access Username and Password for the DDBOOST userAdd the name (FQDN) of the Backup server to the Hosts and the creation works without issue.