
OPERATIONAL DEFECT DATABASE
...

...
User activated or installed two POD licenses at one time with the #licenseadd command on their 6510 switch with two license keys, but only 1 POD kit was activated with 12 ports instead of 24.#switchshow shows only the first POD license took effect: 26 26 0XXXXX id N16 No_Light FC 27 27 0XXXXX id N16 No_Light FC 28 28 0XXXXX id N16 No_Light FC 29 29 0XXXXX id N16 No_Light FC 30 30 0XXXXX id N16 No_Light FC 31 31 0XXXXX id N16 No_Light FC 32 32 0XXXXX id N8 No_Light FC 33 33 0XXXXX id N8 No_Light FC 34 34 0XXXXX id N8 No_Light FC 35 35 0XXXXX id N8 No_Light FC 36 36 0XXXXX id N16 No_Light FC (No POD License) Disabled 37 37 0XXXXX id N16 No_Light FC (No POD License) Disabled 38 38 0XXXXX id N16 No_Light FC (No POD License) Disabled 39 39 0XXXXX id N16 No_Light FC (No POD License) Disabled 40 40 0XXXXX id N16 No_Light FC (No POD License) Disabled 41 41 0XXXXX id N16 No_Light FC (No POD License) Disabled 42 42 0XXXXX id N16 No_Light FC (No POD License) Disabled 43 43 0XXXXX id N16 No_Light FC (No POD License) Disabled 44 44 0XXXXX id N16 No_Light FC (No POD License) Disabled 45 45 0XXXXX id N16 No_Light FC (No POD License) Disabled 46 46 0XXXXX id N16 No_Light FC (No POD License) Disabled 47 47 0XXXXX id N16 No_Light FC (No POD License) Disabled licenseshow shows the first POD license twice: Switch:FID128:admin> licenseshow Extended Fabric license Fabric Watch license Performance Monitor license Trunking license Adaptive Networking license Server Application Optimization license First Ports on Demand license - additional 12 port upgrade license First Ports on Demand license - additional 12 port upgrade license Removing all keys, rebooting the switch and re-adding the keys one at a time did not resolve the issue.
License keys were not added one at a time.
Work Around There is no workaround. Resolution: Replacing both POD keys resolved the issue. After regenerating both POD license keys and adding each license separately, all 24 ports were activated and licenseshow displayed the licenses correctly. Switch:FID128:admin> licenseshow Extended Fabric license Fabric Watch license Performance Monitor license Trunking license Adaptive Networking license Second Ports on Demand license - additional 12 port upgrade license Full Ports on Demand license - additional 24 port upgrade license
Click on a version to see all relevant bugs
Dell Integration
Learn more about where this data comes from
Bug Scrub Advisor
Streamline upgrades with automated vendor bug scrubs
BugZero Enterprise
Wish you caught this bug sooner? Get proactive today.