Data Domain: Interfaces are not compatible for bondingLink Aggregation failing for eth13 and eth5aeth3 and eth10 are QLogic cards and eth5 and eth13 are Intel cards.eth3a,eth3c,eth10a,eth10c (qLoginc 10GbE NICs) were already in the bond veth0, when the customer tried to add eth13a and eth5a (Intel 10GbE NICs) to veth0.We do not support mixed vender bonding with LTS 7.7.4. Net Show Hardware ----------------- Port Speed Duplex Supp Speeds Hardware Address Physical Link Status State ------ ------- ------- ----------- ----------------- -------- ----------- ------- eth3a 10Gb/s full 10000 f4:c7:aa:1b:9a:f4 Fiber yes running eth3c 10Gb/s full 10000 f4:c7:aa:1b:9a:f4 Fiber yes running eth5a unknown unknown 10000 6c:fe:54:2e:2a:0c Fiber unknown down eth10a 10Gb/s full 10000 f4:c7:aa:1b:9a:f4 Fiber yes running eth10c 10Gb/s full 10000 f4:c7:aa:1b:9a:f4 Fiber yes running eth13a unknown unknown 10000 6c:fe:54:2e:56:a0 Fiber unknown down IO Cards: Slot Device FW Revision Interface Ports MAC/WWNN/WWPN/SASADDR ---- -------------------------- ----------- --------- ------ ----------------------- M QL41164 4x 10GBase-T (NDC) 15.35.09 10GbE ethMa f4:c7:aa:5f:16:80 ethMb f4:c7:aa:5f:16:80 ethMc f4:c7:aa:5f:16:82 ethMd f4:c7:aa:5f:16:83 3 QL41164 4x 10GbE SFP+ 15.35.09 10GbE eth3a f4:c7:aa:1b:9a:f4 eth3b f4:c7:aa:1b:9a:f5 eth3c f4:c7:aa:1b:9a:f4 eth3d f4:c7:aa:1b:9a:f7 4 QL41164 4x 10GBase-T 15.35.09 10GbE eth4a f4:c7:aa:57:62:64 eth4b f4:c7:aa:57:62:65 eth4c f4:c7:aa:57:62:66 eth4d f4:c7:aa:57:62:67 5 X710 4x 10GbE SFP+ 20.5.13 10GbE eth5a 6c:fe:54:2e:2a:0c eth5b 6c:fe:54:2e:2a:0d eth5c 6c:fe:54:2e:2a:0e eth5d 6c:fe:54:2e:2a:0f 8 QL41164 4x 10GBase-T 15.35.09 10GbE eth8a f4:c7:aa:57:62:3c eth8b f4:c7:aa:57:62:3d eth8c f4:c7:aa:57:62:3e eth8d f4:c7:aa:57:62:3f 9 PMC Quad Port 12 Gbps SAS 03.09.39.00 PMC_SAS3 9a 50:02:18:8a:25:63:00:dd 9b 50:02:18:8a:25:62:00:dd 9c 50:02:18:8a:25:60:00:dd 9d 50:02:18:8a:25:61:00:dd 10 QL41164 4x 10GbE SFP+ 15.35.09 10GbE eth10a f4:c7:aa:1b:9a:f4 eth10b f4:c7:aa:1b:b3:7d eth10c f4:c7:aa:1b:9a:f4 eth10d f4:c7:aa:1b:b3:7f 12 PMC Quad Port 12 Gbps SAS 03.09.39.00 PMC_SAS3 12a 50:02:18:8d:25:63:00:dd 12b 50:02:18:8d:25:62:00:dd 12c 50:02:18:8d:25:60:00:dd 12d 50:02:18:8d:25:61:00:dd 13 X710 4x 10GbE SFP+ 20.5.13 10GbE eth13a 6c:fe:54:2e:56:a0 eth13b 6c:fe:54:2e:56:a1 eth13c 6c:fe:54:2e:56:a2 eth13d 6c:fe:54:2e:56:a3 ---- -------------------------- ----------- --------- ------ ----------------------- 14:18:11 ddsh: NOTICE: MSG-DDSH-00017: (tty=pts/0, session=5656, client_IP=XX.XX.XX.XX)) sysadmin: command "net aggregate add veth0 interfaces eth13a eth5a mode lacp hash xor-L3L4" exited with code: 9 Aug 8 14:19:30 ddsh: NOTICE: MSG-DDSH-00017: (tty=pts/0, session=5656, client_IP=XX.XX.XX.XX)) sysadmin: command "net aggregate add veth0 interfaces eth5a mode lacp hash xor-L3L4" exited with code: 9 // ddsh.info 07/24 03:50:34.189982 [1c8b3a0] NOTICE: MSG-DDSH-00009: (tty=ttyS0, session=25082, client_IP=) sysadmin: command "net aggregate add veth0 interfaces eth3a eth3c eth10a eth10c mode lacp hash xor-L3L4" 08/07 19:54:12.090579 [1c8b3a0] NOTICE: MSG-DDSH-00017: (tty=ttyS0, session=28106, client_IP=) sysadmin: command "net aggregate add veth0 interfaces eth5a eth13a" exited with code: 9 08/07 19:54:48.264620 [1c8b3a0] NOTICE: MSG-DDSH-00017: (tty=ttyS0, session=28106, client_IP=) sysadmin: command "net aggregate add veth0 interfaces eth5a eth13a mode lacp hash xor-L3L4" exited with code: 9 08/07 19:55:28.171618 [1c8b3a0] NOTICE: MSG-DDSH-00017: (tty=ttyS0, session=28106, client_IP=) sysadmin: command "net aggregate add veth0 interfaces eth5a" exited with code: 9 08/07 19:56:55.771063 [1c8b3a0] NOTICE: MSG-DDSH-00017: (tty=ttyS0, session=28106, client_IP=) sysadmin: command "net aggregate add veth0 interfaces eth3a eth3c eth10a eth10c eth5a eth13a mode lacp hash xor-L3L4" exited with code: 9 08/07 19:58:36.159861 [1c8b3a0] NOTICE: MSG-DDSH-00009: autosupport: command "net aggregate show" 08/07 20:00:55.334117 [1c8b3a0] NOTICE: MSG-DDSH-00009: (tty=ttyS0, session=28106, client_IP=) sysadmin: command "net aggregate add veth0 interfaces eth3a eth3c eth10a eth10c mode lacp hash xor-L3L4" 08/07 20:02:53.962776 [1c8b3a0] NOTICE: MSG-DDSH-00017: (tty=ttyS0, session=28106, client_IP=) sysadmin: command "net aggregate add veth0 interfaces eth5a" exited with code: 9 08/07 20:03:41.137336 [1c8b3a0] NOTICE: MSG-DDSH-00017: (tty=ttyS0, session=28106, client_IP=) sysadmin: command "net aggregate add veth0 interfaces eth5a mode lacp hash xor-L3L4" exited with code: 9 08/07 20:12:05.809219 [1c8b3a0] NOTICE: MSG-DDSH-00017: (tty=ttyS0, session=28106, client_IP=) sysadmin: command "net aggregate add veth0 interfaces eth5a eth13a" exited with code: 9 08/07 20:12:47.520932 [1c8b3a0] NOTICE: MSG-DDSH-00017: (tty=ttyS0, session=28106, client_IP=) sysadmin: command "net aggregate add veth0 interfaces eth5a eth13a" exited with code: 9 08/08 07:00:45.139723 [1c8b3a0] NOTICE: MSG-DDSH-00009: autosupport: command "net aggregate show" 08/08 14:15:44.388855 [1c8b3a0] NOTICE: MSG-DDSH-00009: (tty=pts/0, session=5656, client_IP=XX.XX.XX.XX) sysadmin: command "net aggregate show" 08/08 14:18:11.880653 [1c8b3a0] NOTICE: MSG-DDSH-00017: (tty=pts/0, session=5656, client_IP=XX.XX.XX.XX)sysadmin: command "net aggregate add veth0 interfaces eth13a eth5a mode lacp hash xor-L3L4" exited with code: 9 08/08 14:19:30.481604 [1c8b3a0] NOTICE: MSG-DDSH-00017: (tty=pts/0, session=5656, client_IP=XX.XX.XX.XX)sysadmin: command "net aggregate add veth0 interfaces eth5a mode lacp hash xor-L3L4" exited with code: 9 08/08 14:19:42.967674 [1c8b3a0] NOTICE: MSG-DDSH-00017: (tty=pts/0, session=5656, client_IP=XX.XX.XX.XX)) sysadmin: command "net aggregate add veth0 interfaces eth13a mode lacp hash xor-L3L4" exited with code: 9
Bonded interface configuration guidelines ...Bonded interfaces must be created from identical physical interfaces. For example, all copper, all optical, all 1 Gb, or all 10 Gb. However, 1 Gb interfaces support bonding a mix of copper and optical interfaces. This applies to bonded interfaces across different cards with identical physical interfaces.
Hence we do not support mixed vendor bonding with LTS 7.7.4. It is supported in DDOS 7.12. https://dl.dell.com/content/manual64332191-ddos-7-12-administration-guide.pdf?language=en-us NOTE: In DDOS 7.12 and higher, the system no longer checks the NIC vendor when adding interfaces from multiple NIC cards to a bonded interface.