Symptoms
The System Check in the off-release health check package may identify an invalid target group id. This issue is described in KB 000216639 PowerStore: Mapping an NVMeoF volume may lead to service disruption on multi-appliance clusters. The issue is detected in the following scenarios:
Running a System Check using PowerStore Manager (UI) with the Run System Check option:
Running the System Health Service Script (svc_health_check) using an SSH connection: Note: Output truncated for illustrative purposes.
[SVC:cyc@ABCDEF-A ~]$ svc_health_check run -rhc target_port_group_id_check Name Location Status Description Target PortGroup Id Check node_a Failed Max value of LOCAL target_port_group_id is over the max threshold of 29. (KB000216953)
Cause
After multiple add appliance failures, the target group id may be assigned a value outside of the valid range. This will impact the cluster when NVMEoF host mapping is being used.
Resolution
Contact technical support for assistance in resolving this issue. This should be resolved ASAP.If not resolved, there is a high risk of the node may enter service mode or go down affecting the High Availability of the appliance. This issue is planned to be resolved in a future PowerStoreOS release.