Symptoms
After running scanner on a tape volume, a saveset will only show the final fragment address in mminfo, for example:
mminfo -ar ssid,mediafile,mediarec,first,last,fragsize,fragflags -q volume=volume_name
ssid media-file record first last frag-size frag-flags
3989758634 26 0 51140091900 51203151695 61 MB cb
Lack of a fragment in mminfo showing first value of 0 (true start of saveset).Error attempting even saveset recovery: Recover failed from NSR server `server': No volumes found for recover.
Cause
This issue is a result of enhancement for disk-family media in NetWorker 19.5 and above.
Resolution
The code fix will be available in upcoming versions of NetWorker 19.6.1.2 or .3 and 19.7.0.1.Workaround:
Add the -F switch as part of scanner command.
NOTE: This will change saveset retention even if the saveset already exists in the media database (-y switch can be used to set retention manually).
Use the standalone scanner binary from an earlier version, ideally 19.4.0.6