Symptoms
After upgrade to ESXi 6.0 build-10474991 below errors started to appear. (HBA driver 2.1.50.0-1vmw.600.3.57.5050593 and later)EnvironmentHost model: ProLiant BL460c Gen8ESXi VMware ESXi 6.0.0 build-10719132HBA QLogic Corp 2600 Series 16Gb Fibre Channel to PCI Express HBAHBA driver 2.1.73.0-1OEM.600.0.0.2768847 PowerPath/VE 6.xUnity 450F Software 4.3.1.1525703027Symptoms:When hosts were running VMware ESXi 6.0.0 build-6921384 (or earlier) Unity LUNs were not erroring.After upgrade to ESXi 6.0 build-10474991 below errors started to appear. (HBA driver 2.1.50.0-1vmw.600.3.57.5050593 and later) extract from vobd.log2018-11-28T04:15:30.337Z: [scsiCorrelator] 1176699738791us: [vob.scsi.scsipath.pathstate.dead] scsiPath vmhba2:C0:T2:L14 changed state from on2018-11-28T04:15:30.337Z: [scsiCorrelator] 1176687116200us: [esx.problem.storage.redundancy.degraded] Path redundancy to storage device naa.600601600xxxxxxxxxxxxxxxxxxxxxx degraded. Path vmhba2:C0:T2:L14 is down. Affected datastores: Unknown.2018-11-28T04:15:30.441Z: [scsiCorrelator] 1176699843060us: [vob.scsi.scsipath.pathstate.on] scsiPath vmhba2:C0:T2:L14 changed state from dead2018-11-28T04:15:30.442Z: [scsiCorrelator] 1176687220485us: [esx.clear.storage.redundancy.restored] Path redundancy to storage device naa.600601600xxxxxxxxxxxxxxxxxxxxxxx (Datastores: Unknown) restored. Path vmhba2:C0:T2:L14 is active again. extract from vmkernel.log2018-11-28T04:15:30.336Z cpu19:33424)Debug:PowerPath:Path vmhba2:C0:T2:L14 CMD 12 Recieved platform Status Success SCSI Status: H:0xc D:0x0 P:0x02018-11-28T04:15:30.336Z cpu19:33424)Debug:PowerPath:Path vmhba2:C0:T2:L14 CMD 12 Recieved platform Status Success SCSI Status: H:0xc D:0x0 P:0x02018-11-28T04:15:30.336Z cpu19:33424)Debug:PowerPath:Path vmhba2:C0:T2:L14 CMD 12 Recieved platform Status Success SCSI Status: H:0xc D:0x0 P:0x02018-11-28T04:15:30.336Z cpu19:33424)Debug:PowerPath:Path vmhba2:C0:T2:L14 CMD 12 Recieved platform Status Success SCSI Status: H:0xc D:0x0 P:0x02018-11-28T04:15:30.336Z cpu19:33424)PowerPath:Path vmhba2:C0:T2:L14 probe failed with Status Success H:0x0 P:0x0 D:0x02018-11-28T04:15:30.336Z cpu19:33424)PowerPath:Path "vmhba2:C0:T2:L14" is changing to dead from on.2018-11-28T04:15:30.336Z cpu19:33424)Debug:PowerPath:Path vmhba2:C0:T2:L14 CMD 12 Recieved platform Status Success SCSI Status: H:0xc D:0x0 P:0x02018-11-28T04:15:30.441Z cpu19:33424)PowerPath:Path "vmhba2:C0:T2:L14" is changing to on from dead.
Cause
Cause (from VMware driver team):There is a change in ESXi 6.0 EP15 compared with ESXi 6.0 P06: In case H:0xc error is reported, we will retry the command at driver layer instead of HBA layer.This was done to avoid adapter queue full conditions.
Resolution
Install the HBA driver 2.1.81.0 (or above) and firmware 8.08 (or above) as per VMware HCL