Symptoms
Warning: Dell Data Protection | Hardware Crypto-Accelerator is End of Life for more information, reference End of Life / End of Support policy for Dell Data Security.
Affected Products:
Dell Encryption Enterprise Self-Encrypting DriveDell Data Protection | Self-Encrypting DriveDell Data Protection | Hardware Crypto-Accelerator
Resolution
Self-Encrypting Drive or Hardware Crypto-Accelerator and SmartCard: no valid method error at PBA
After configuring HCA or SED with smart card PBA authentication, the end user cannot authenticate successfully with the following error in the PBA logs:
CredException: User::Authenticate() - invalid method is used (Error code: 0)
Regenerating the domain controller Authentication certificate on the domain controller fixes this issue. This certificate is required for smart card log in authentication.