Symptom
snmpbulkget cannot get loss, latency and jitter for "appRouteStatisticsAppProbeClassTable" and "appRouteStatisticsAppProbeClassIntervalTable" OIDs
Conditions
Any cedge device
or C1111X-8P
has BFD tunnels
use snmpbulkget from the tool and use max repetition as 500 like ( -Cr500) to get 500 values but bulkget doesn't return loss, latency and jitter values
Workaround
Use ( snmpwalk) operation
Further Problem Description
snmpbulkget cannot get loss, latency and jitter for "appRouteStatisticsAppProbeClassTable" and "appRouteStatisticsAppProbeClassIntervalTable" OIDs
Below are sample of the issue:
$ snmpbulkget -Cr500 ce1 1.3.6.1.4.1.9.9.1001.1.5
CISCO-SDWAN-APP-ROUTE-MIB::appRouteStatisticsAppProbeClassName."..d."."..d.".12366.12426.2."None" = STRING: None
CISCO-SDWAN-APP-ROUTE-MIB::appRouteStatisticsAppProbeClassName."..d."."..d.".12366.12426.2."PG-test-apc" = STRING: PG-test-apc
CISCO-SDWAN-APP-ROUTE-MIB::appRouteStatisticsAppProbeClassName."..d."."..d.".12366.12426.2."PG-test-apc2" = STRING: PG-test-apc2
CISCO-SDWAN-APP-ROUTE-MIB::appRouteStatisticsAppProbeClassName."..d."."..d.".12366.12426.2."PG-test-apc3" = STRING: PG-test-apc3
$ snmpbulkget -Cr500 ce1 1.3.6.1.4.1.9.9.1001.1.6
CISCO-SDWAN-APP-ROUTE-MIB::appRouteStatisticsAppProbeClassIntervalTotalPackets."..d."."..d.".12366.12426.2."None".0 = INTEGER: 24
CISCO-SDWAN-APP-ROUTE-MIB::appRouteStatisticsAppProbeClassIntervalTotalPackets."..d."."..d.".12366.12426.2."None".1 = INTEGER: 23
CISCO-SDWAN-APP-ROUTE-MIB::appRouteStatisticsAppProbeClassIntervalTotalPackets."..d."."..d.".12366.12426.2."None".2 = INTEGER: 24
CISCO-SDWAN-APP-ROUTE-MIB::appRouteStatisticsAppProbeClassIntervalTotalPackets."..d."."..d.".12366.12426.2."PG-test-apc".0 = INTEGER: 24
CISCO-SDWAN-APP-ROUTE-MIB::appRouteStatisticsAppProbeClassIntervalTotalPackets."..d."."..d.".12366.12426.2."PG-test-apc".1 = INTEGER: 23
to see full outputs in defect attachements.
The issue is reproduced in TAC lab C1111X-8P running 17.9.3a CCO image
when we use snmpwalk , we got full outputs and we see the loss, latency and jitter values but the customer needs to use snmpbulkget