Symptom
The last reload reason shows Critical process qfp_ucode_utah fault on fp_0_0 (rc=139).
First time documented was in ISR4331-DC/K9 with Version 17.09.02a but it may happen in previous codes or none fixed releases.
This event generates a system report with a core file inside.
Conditions
Happen during normal operations.
Unexpected reload happens when a malformed packet is tried to be processed. When the device is not able to determine the kind of packet the device crashes. There will be added in the fix a mechanism to discard that kind of packets before try to process them.
Workaround
Not work around by the moment, still in review.
Further Problem Description
If you suspect that you are hitting this bug, please open a case with TAC and collect show tech and system report to attach them to the case.