Symptom
LPTS drops after ASIC reset
show lpts pifib hardware police location all
-------------------------------------------------------------
Node 0/RP0/CPU0:
-------------------------------------------------------------
FlowType Policer Type Cur. Rate Burst Accepted Dropped npu
---------------------- ------- ------- --------- --------- ------------ ------------ ---------
LDP-UDP 31 np 523 1000 13333113 42701 0
Conditions
ASIC SOFT reset because of interrupts, e.g. (can be different)
reg.rx_beat_err
reg.rx_fatal_eof_err
npu_drvr[292]: %FABRIC-NPU_DRVR-3-ASIC_ERROR_ACTION : [5868] : npu[0]: HARD_RESET needed for slice[4].ifg[1].ifgb.rx_prot_interrupt_reg.rx_beat_err
npu_drvr[292]: %FABRIC-NPU_DRVR-3-ASIC_ERROR_ACTION : [5868] : npu[0]: HARD_RESET needed for slice[4].ifg[1].ifgb.rx_prot_interrupt_reg.rx_fatal_eof_err
Further Problem Description
Recovery:
Depends on policer affected.
In case of LDP polcier affected Recovery action is: "process restart mpls ldp"