Symptom
Hardware : C9300L
Switch reports 'Stack Adapter Authentication Failed' on bootup.
***Stack adapter authentication failed on stack port 2 on switch 1***
Stack Adapter Auth Fail : SIF_SERDES_CABLE_WESTBOUND
Conditions
Switch reports 'Stack Adapter Authentication Failed' on bootup.
No trigger.
Issue occurs on standalone switch as well if stack adapter is connected.
Show inventory output will list stack adapter as part of switch.
NAME: "StackAdapter1/1", DESCR: "StackAdapter1/1"
PID: C9300L-STACK , VID: V02 , SN: FOC2643AZ3M
NAME: "StackAdapter1/2", DESCR: "StackAdapter1/2"
PID: C9300L-STACK , VID: V02 , SN: FOC2643AZ4M
Sometimes, the issue occurs when the switch is added to stack and then disconnected.
Workaround
Power cycle of the switch helps to recover the switch from this scenario.
Further Problem Description
Switch reports 'Stack Adapter Authentication Failed' on bootup.
No trigger.
Sometimes the issue occur when switch is added to stack and then disconnected.
Issue could be recreated by reloading the switch multiple times.