Symptom
Input errors and runts incrementing on interfaces AppGigabitEthernet
AppGigabitEthernet1/0/1 is up, line protocol is up (connected)
Hardware is App-hosting Gigabit Ethernet, address is aaaa.bbbb.cccc (bia aaaa.bbbb.cccc)
MTU 1500 bytes, BW 1000000 Kbit/sec, DLY 10 usec,
reliability 255/255, txload 1/255, rxload 1/255
Encapsulation ARPA, loopback not set
Keepalive set (10 sec)
Full-duplex, 1000Mb/s, media type is App-hosting port
input flow-control is on, output flow-control is unsupported
ARP type: ARPA, ARP Timeout 04:00:00
Last input never, output 00:00:01, output hang never
Last clearing of "show interface" counters never
Input queue: 0/2000/0/0 (size/max/drops/flushes); Total output drops: 0
Queueing strategy: fifo
Output queue: 0/40 (size/max)
5 minute input rate 0 bits/sec, 0 packets/sec
5 minute output rate 0 bits/sec, 0 packets/sec
0 packets input, 91 bytes, 0 no buffer
Received 0 broadcasts (0 multicasts)
18 runts, 0 giants, 0 throttles
20 input errors, 0 CRC, 0 frame, 0 overrun, 0 ignored
0 watchdog, 0 multicast, 0 pause input
0 input packets with dribble condition detected
1045751 packets output, 96159303 bytes, 0 underruns
Output 106 broadcasts (893052 multicasts)
0 output errors, 0 collisions, 2 interface resets
0 unknown protocol drops
0 babbles, 0 late collision, 0 deferred
0 lost carrier, 0 no carrier, 0 pause output
0 output buffer failures, 0 output buffers swapped out
Conditions
Interfaces are in up/up state
No configurations applied on the interfaces
No applications hosted
Workaround
There is no workaround at this time - however without Application Hosting running, this issue should not impact user traffic.